MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcha.2020.100593

Медицинская библиотека · International journal of cardiology. Heart & vasculature · 2020

Undersizing but overfilling eliminates the gray zones of sizing for transcatheter aortic valve replacement with the balloon-expandable bioprosthesis.

Patsalis Polykarpos C, Kloppe Axel, Plicht Björn, Schöne Dominik, Schiedat Fabian, Aweimer Assem, Kara Kaffer, Haldenwang Peter Lukas, Strauch Justus Thomas, Buck Thomas, Mügge Andreas

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Current recommendations for valve size selection are based on multidimensional annular measurements, yet the overlap between two different transcatheter heart valve (THV) sizes remains. We sought to evaluate whether undersizing but overfilling eliminates the gray zones of valve sizing.

METHODS

Data of 246 consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with the balloon-expandable bioprosthesis with either conventional sizing and nominal filling (group 1 (NF-TAVR), n = 154) or undersizing but overfilling under a Less Is More (LIM)-Principle (group 2 (LIM-TAVR), n = 92) were compared. Paravalvular leakage (PVL) was graded angiographically and quantitatively using invasive hemodynamics.

RESULTS

Annulus rupture (AR) occurred only in group 1 (n = 3). Due to AR adequate evaluation of PVL was possible in 152 patients of group 1. More than mild PVL was found in 13 (8.6%) patients of group 1 and 1 (1.1%) patient of group 2 (p = 0.019). Postdilatation was performed in 31 (20.1%) patients of group 1 and 6 patients (6.5%) of group 2 (p = 0.003). For patients with borderline annulus size in group 1 (n = 35, 22.7%) valve size selection was left to the physiciańs choice resulting in selection of the larger prosthesis in 10 (28.6%). In group 2 all patients with borderline annulus (n = 36, 39.1%) received the smaller prosthesis (LIM-TAVR). The postprocedural mean transvalvular pressure gradient was significantly higher in the NF-TAVR-group (11.7 ± 4 vs. 10.1 ± 3.6 mmHg, p = 0.005).

CONCLUSION

LIM-TAVR eliminates the gray zones of sizing and associated PVL, can improve THV-performance, reduce incidence of annular rupture and simplify the procedure especially in borderline cases.

Для цитирования: Patsalis Polykarpos C, Kloppe Axel, Plicht Björn, Schöne Dominik, Schiedat Fabian, Aweimer Assem, Kara Kaffer, Haldenwang Peter Lukas, Strauch Justus Thomas, Buck Thomas, Mügge Andreas. Undersizing but overfilling eliminates the gray zones of sizing for transcatheter aortic valve replacement with the balloon-expandable bioprosthesis.. International journal of cardiology. Heart & vasculature. 2020. DOI: 10.1016/j.ijcha.2020.100593.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.