MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.artmed.2024.102774

Медицинская библиотека · Artificial intelligence in medicine · 2024

Multi input-Multi output 3D CNN for dementia severity assessment with incomplete multimodal data.

Gravina Michela, García-Pedrero Angel, Gonzalo-Martín Consuelo, Sansone Carlo, Soda Paolo

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Alzheimer's Disease is the most common cause of dementia, whose progression spans in different stages, from very mild cognitive impairment to mild and severe conditions. In clinical trials, Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) are mostly used for the early diagnosis of neurodegenerative disorders since they provide volumetric and metabolic function information of the brain, respectively. In recent years, Deep Learning (DL) has been employed in medical imaging with promising results. Moreover, the use of the deep neural networks, especially Convolutional Neural Networks (CNNs), has also enabled the development of DL-based solutions in domains characterized by the need of leveraging information coming from multiple data sources, raising the Multimodal Deep Learning (MDL). In this paper, we conduct a systematic analysis of MDL approaches for dementia severity assessment exploiting MRI and PET scans. We propose a Multi Input-Multi Output 3D CNN whose training iterations change according to the characteristic of the input as it is able to handle incomplete acquisitions, in which one image modality is missed. Experiments performed on OASIS-3 dataset show the satisfactory results of the implemented network, which outperforms approaches exploiting both single image modality and different MDL fusion techniques.

Для цитирования: Gravina Michela, García-Pedrero Angel, Gonzalo-Martín Consuelo, Sansone Carlo, Soda Paolo. Multi input-Multi output 3D CNN for dementia severity assessment with incomplete multimodal data.. Artificial intelligence in medicine. 2024. DOI: 10.1016/j.artmed.2024.102774.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.