Prospective blinded evaluation of computed tomographic colonography for screen detection of colorectal polyps.

Johnson C Daniel, Harmsen William S, Wilson Lynn A, Maccarty Robert L, Welch Timothy J, Ilstrup Duane M, Ahlquist David A

СтатьяПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

BACKGROUND & AIMS: This study used a low lesion prevalence population reflective of the screening setting to estimate the sensitivity and specificity of computerized tomographic (CT) colonography for detection of colorectal polyps.

METHODS

This prospective, blinded study comprised 703 asymptomatic persons at higher-than-average risk for colorectal cancer who underwent CT colonography followed by same-day colonoscopy. Two of 3 experienced readers interpreted each CT colonography examination.

RESULTS

Overall lesion prevalence for adenomas >/=1 cm in diameter was 5%. Seventy percent of all lesions were proximal to the descending colon. With colonoscopy serving as the gold standard, CT colonography detected 34%, 32%, 73%, and 63% of the 59 polyps >/=1 cm for readers 1, 2, 3, and double-reading, respectively; and 35%, 29%, 57%, and 54% of the 94 polyps 5-9 mm for readers 1, 2, 3, and double-reading, respectively. Specificity for CT colonography ranged from 95% to 98% and 86% to 95% for >1 cm and 5-9-mm polyps, respectively. Interobserver variability was high for CT colonography with kappa statistic values ranging from -0.67 to 0.89.

CONCLUSIONS

In a low prevalence setting, polyp detection rates at CT colonography are well below those at colonoscopy. These rates are less than previous reports based largely on high lesion prevalence cohorts. High interobserver variability warrants further investigation but may be due to the low prevalence of polyps in this cohort and the high impact on total sensitivity of each missed polyp. Specificity, based on large numbers, is high and exhibits excellent agreement among observers.

Для цитирования: Johnson C Daniel, Harmsen William S, Wilson Lynn A, Maccarty Robert L, Welch Timothy J, Ilstrup Duane M, Ahlquist David A. Prospective blinded evaluation of computed tomographic colonography for screen detection of colorectal polyps.. Gastroenterology. 2003. DOI: 10.1016/s0016-5085(03)00894-1.