PURPOSE: To report a case of colonic infarction following endovascular abdominal aortic aneurysm (AAA) repair in a patient with both internal iliac arteries (IIA) unobstructed by the endograft.

CASE REPORT: A 73-year-old man presented with blue toes as a result of emboli from a 6.4-cm AAA. As he was medically at high risk for open repair and his aneurysm morphology was suitable for a modular bifurcated endovascular graft, a Zenith endograft was used to exclude the aneurysm. Twenty hours after the successful procedure, in which both IIAs were preserved, the patient regurgitated coffee-ground vomit; an upper gastrointestinal endoscopy found a small Mallory-Weiss tear and antral gastritis. A proton-pump inhibitor was begun, but his symptoms progressed. Laparotomy revealed transmural ischemia and infarction of the upper rectum, sigmoid, descending colon, and the splenic flexure; a colonic resection with formation of Hartmann's pouch and colostomy was performed. He made a slow but uncomplicated recovery.

CONCLUSIONS

Colonic necrosis can complicate endovascular AAA repair even when both IIAs are preserved. Advantageously, the clinical signs of severe colonic ischemia in endograft patients are not obscured by aftereffects of a laparotomy.

Для цитирования: Hinchliffe Robert J, Armon Matthew P, Tse Chad Cheuk-Wa, Wenham Peter W, Hopkinson Brian R. Colonic infarction following endovascular AAA repair: a multifactorial complication.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2002. DOI: 10.1177/152660280200900428.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.