DOI 10.1177/1051228405001523

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2006

Volume flow rate of common carotid artery measured by Doppler method and Color Velocity Imaging Quantification (CVI-Q).

Likittanasombut Pornpatr, Reynolds Patrick, Meads Dana, Tegeler Charles

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Common carotid artery (CCA) volume flow rate (VFR) is clinically useful for study of cerebrovascular disease. Color Velocity Imaging Quantification (CVI-Q; Philips Ultrasound International, Irvine, CA), previously reported as accurate and reliable, tracks the flow lumen over the cardiac cycle, as well as mean spatial velocity, which is multiplied by vessel area to obtain VFR. VFR can also be obtained by Doppler sampling for mean velocity, and vessel area based on static B-mode lumen diameter. We compared CCA VFR by CVI-Q and Doppler method (DM), since knowledge of how they compare is crucial when both are used clinically.

METHOD: We prospectively studied patients having clinical carotid duplex exams and healthy controls. All had CCA VFR measured by both methods in the same exam session.

RESULTS

Thirty-four studies were reviewed. CCA VFR by CVI-Q in those without ICA stenosis was 337 +/- 96 mL/m, and by DM 359 +/- 130 mL/m; P = .33. There was no difference between methods for 50-75% or 75-95% ICA stenosis. In 7 patients with ICA occlusion, and 3 with 95-99% stenosis, VFR was higher by DM than by CVI-Q (Occlusion: 125 vs 58 mL/m, P = .007; 95-99%: 152 vs 63 mL/m, P = .038). There was no statistically significant difference between methods for measurement of the ratio of VFR between right and left CCA.

CONCLUSION

In patients with 0-95% ICA stenosis, VFR by CVI-Q and DM showed no difference. For 95-100% ICA stenosis the methods differ; with higher VFR by DM. Side-to-side VFR ratios remain constant, irrespective of VFR method, and can still provide clinically useful information.

Для цитирования: Likittanasombut Pornpatr, Reynolds Patrick, Meads Dana, Tegeler Charles. Volume flow rate of common carotid artery measured by Doppler method and Color Velocity Imaging Quantification (CVI-Q).. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2006. DOI: 10.1177/1051228405001523.