MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.rli.0000192416.19801.ca

Медицинская библиотека · Investigative radiology · 2006

Time-resolved contrast enhanced magnetic resonance angiography of the head and neck at 3.0 tesla: initial results.

Nael Kambiz, Michaely Henrik J, Villablanca Pablo, Salamon Noriko, Laub Gerhard, Finn J Paul

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We sought to implement and evaluate a high-performance, extended field of view protocol for time-resolved contrast-enhanced magnetic resonance imaging (CEMRA) of the carotid circulation by using a dedicated neurovascular (NV) array coil.

MATERIALS AND

METHODS

A total of 16 adult volunteers and 20 clinical patients with suspected cerebrovascular disease (15 male, 21 female, 25-82 years of age) were scanned with a fast 3D MRA sequence (TR/TE: 2.16/1 milliseconds, sampling BW: 1090 Hz/pixel), with echo-sharing and parallel acquisition. All studies were performed on a 3.0 T MR system using an 8-channel neurovascular array coil. After injection of 6 mL of gadodiamide at 3 mL/s, a coronal 3D data set with in-plane resolution of 1 x 1.3 was implemented for 10 consecutive measurements each 1.8 seconds apart. The subjects subsequently underwent high spatial-resolution (in-plane: 0.8 x 0.9) CEMRA for comparative analysis. The quality of segmental arterial anatomy and the presence and degree of the arterial stenosis were evaluated by 2 neuroradiologists. The interobserver variability was tested by kappa statistics and comparative analysis between the TR-CEMRA and high spatial-resolution CEMRA was evaluated by mean of the Spearman rank correlation coefficient.

RESULTS

Craniocervical arteries were visualized with good image quality and definition in the diagnostic range. Occlusive disease was detected in 42 (reader A) and 44 (reader B) arterial segments with excellent interobserver agreement (kappa =0.89; 95% confidence interval 0.82-0.96). There was a significant correlation between the TR-CEMRA and high spatial-resolution CEMRA (Rs = 0.91 and 0.93, for readers A and B, respectively) for the degree of stenosis. Three aneurysms, 3 AVMs, 1 AV-fistula, and 2 subclavian steals were detected by both observers and were confirmed by correlative imaging.

CONCLUSION

Time-resolved CEMRA at 3.0 T is reliable and versatile, providing 3-dimensional time-resolved data sets with high spatial (in plane: 1.3 x 1 mm2) and temporal (1.8 seconds) resolution over a large field of view. The higher signal-to-noise ratio gain at 3.0 T can be used effectively to improve performance of fast imaging and to support aggressive parallel acquisition protocols, as in the present study. Further clinical studies are required to establish the range of applications and the accuracy of the technique.

Для цитирования: Nael Kambiz, Michaely Henrik J, Villablanca Pablo, Salamon Noriko, Laub Gerhard, Finn J Paul. Time-resolved contrast enhanced magnetic resonance angiography of the head and neck at 3.0 tesla: initial results.. Investigative radiology. 2006. DOI: 10.1097/01.rli.0000192416.19801.ca.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.