DOI 10.1016/s0167-5273(98)00374-x
Balloon mitral valvuloplasty: comparison of haemodynamic and echocardiographic assessment of mitral stenosis at different heart rates in the catheterisation laboratory.
Аннотация
AIMS: To compare echo-Doppler, Gorlin equation and haemodynamic methods of measuring mitral valve stenosis during right ventricular pacing-induced tachycardia before and after Inoue balloon mitral valvuloplasty to determine which method gave the most consistent results.
METHODS AND
RESULTS
Measurements were made before and after valvuloplasty at: baseline heart rates, paced at 115 and then 145 beats/min. Mitral valve area by echo-Doppler was 1.1(+/-0.1) cm2 (mean +/- S.E.) before and 1.8(+/-0.2) cm2 after valvuloplasty; and by Gorlin equation: 0.9(+/-0.1) cm2 before and 1.5(+/-0.1) cm2 after. Echo-Doppler measurements were heart rate dependent but those by Gorlin measurements were not. At baseline, cardiac index was 2.08(+/-0.2) l min(-1), left atrial pressure 23.3(+/-7.9) mm Hg and mean mitral diastolic gradient 16.9(+/-9.9) mm Hg. After valvuloplasty, cardiac index was 2.31(+/-0.1) l min(-1), left atrial pressure fell to 19.2(+/-5.6) mm Hg and mean diastolic gradient was reduced to 8.5(+/-1.8) mm Hg.
CONCLUSIONS
The Gorlin mitral valve area appeared to be the most heart rate independent indicator of success following valvuloplasty.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.