Left atrial appendage function in mitral stenosis: is a group in sinus rhythm at risk of thromboembolism?

Daimee M A, Salama A L, Cherian G, Hayat N J, Sugathan T N

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To study the left atrial appendage (LAA) function and potential for embolization in severe mitral stenosis (MS).

BACKGROUND

Patients with MS and atrial fibrillation or in sinus rhythm develop systemic emboli. LAA function has not been well studied in sinus rhythm.

METHODS

Forty consecutive patients with MS (valve area < or =0.7 cm2/m2) were studied. LAA ejection fraction and peak emptying velocity were measured along with other data.

RESULTS

Patients were subgrouped according to LAA Doppler flow pattern. Group I (n=13) in sinus rhythm had biphasic high velocity > or =25 cm/s. Group II (n=13) in sinus rhythm had biphasic low velocity <25 cm/s. Group III (n=14) in atrial fibrillation had multiphasic irregular flow <25 cm/s or no definite flow. The LAA ejection fraction and peak emptying velocity were strikingly different in all groups. They were lower in group II when compared to group I. Group II had intermediate risk for thromboembolism compared to Group I and III as judged by systemic embolization, spontaneous echo contrast, thrombus in left atrium and LAA.

CONCLUSION

A subset of mitral stenosis in sinus rhythm at increased risk of embolization can be suspected by Doppler transesophageal echocardiographic LAA flow profile.

Для цитирования: Daimee M A, Salama A L, Cherian G, Hayat N J, Sugathan T N. Left atrial appendage function in mitral stenosis: is a group in sinus rhythm at risk of thromboembolism?. International journal of cardiology. 1998. DOI: 10.1016/s0167-5273(98)00128-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.