MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10554-020-02047-5

Медицинская библиотека · The international journal of cardiovascular imaging · 2020

Comparison of serial optical coherence tomography imaging following aggressive stent expansion technique: insight from the MECHANISM study.

Sasaki Wataru, Ishida Masaru, Itoh Tomonori, Uchimura Yohei, Oda Hideto, Taguchi Yuya, Kaneko Kyosuke, Sakamoto Tsubasa, Goto Iwao, Sakuma Masafumi, Terashita Daisuke, Otake Hiromasa, Shinke Toshiro, Morino Yoshihiro

Сравнительное исследованиеСтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

To compare early vascular healing following cobalt-chromium everolimus-eluting stent (CoCr-EES) implantation between groups with or without aggressive stent expansion in patients treated by CoCr-EES for stable coronary artery disease (CAD). Seventy-one stable CAD lesions underwent CoCr-EES implantation and analysis of serial optical coherence tomography (OCT) images obtained post-procedure and at early-term (1- or 3-month) follow-up. The endpoints of this study were neointimal thickness at the time of 1- or 3-month OCT and presence and healing of stent edge dissection. Aggressive stent expansion was defined as a lesion complying with ILUMIEN III sizing protocol; that is, external elastic lamina (EEL) diameter minus maximum balloon diameter ≤ 0.25 mm.  Comparing groups with and without aggressive stent expansion, median neointimal thickness at 1 and 3 months after CoCr-EES implantation was similar (1 month: 0.031 mm vs. 0.041 mm, respectively, p = 0.27; 3 months: 0.036 mm vs. 0.040 mm, respectively, p = 0.84). Regarding stent edge findings, the presence of any stent edge dissection immediately after percutaneous coronary intervention was also similar between the groups (25% vs. 15%, respectively; p = 0.30) and most stent edge dissections resolved completely within 3 months, regardless of location or dissection severity. After 1 year, no clinically driven target lesion revascularization or stent thrombosis was observed in either cohort. Even after aggressive stent expansion, early neointimal proliferation appeared modest with CoCr-EES implantation, and most stent edge dissections had resolved by 3 months. These findings may support the feasibility of EEL-based sizing by pre-stenting OCT.

Для цитирования: Sasaki Wataru, Ishida Masaru, Itoh Tomonori, Uchimura Yohei, Oda Hideto, Taguchi Yuya, Kaneko Kyosuke, Sakamoto Tsubasa, Goto Iwao, Sakuma Masafumi, Terashita Daisuke, Otake Hiromasa, Shinke Toshiro, Morino Yoshihiro. Comparison of serial optical coherence tomography imaging following aggressive stent expansion technique: insight from the MECHANISM study.. The international journal of cardiovascular imaging. 2020. DOI: 10.1007/s10554-020-02047-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.