BACKGROUND

The Orsiro cobalt-chromium stent platform (Biotronik, Bülach, Switzerland) is one of the first devices in the era of ultrathin struts. However, data regarding the efficacy of Orsiro stent in patients with challenging anatomical conditions obtained from daily clinical practice are scant.

METHODS

We retrospectively reviewed the long-term outcomes, defined as target lesion revascularization (TLR), target vessel revascularization (TVR), stent thrombosis (ST) and cardiovascular (CV) mortality over a six years period, in 1161 consecutive patients (mean age 64.3 ± 11.2 years old, 681 males) treated with 2327 Orsiro stents in our institution who presented with challenging anatomic/angiographic features.

RESULTS

The mean number of implanted stents was 1.7 ± 2.1 whereas the mean stent diameter and length were 3.6 ± 1.1 and 32.7 ± 15.6 mm, respectively. Mean follow-up duration was 35.6 ± 17 months (range 1-77 months); 923 patients (79.5%) reached the 3-year follow-up. The global rates of TLR, TVR, ST and CV mortality were 0.1%, 1.37%, 0.002%, and 1.9%, respectively with scarce statistically significant differences in multivessel disease, severe calcification, and lesion length > 41 mm. Multivariate regression analysis revealed that age, stent dislodgement, early stent thrombosis (p = 0.001) and lesion length ≥ 41 mm (p = 0.001) were independent predictors of TVR. Similarly, the occurrence of TLR was independently predicted by age, severe calcification, use of IVUS and Rotablator (p = 0.002), early stent thrombosis, LM bifurcation and length ≥ 41 mm (p = 0.001).

CONCLUSIONS

The Orsiro stent confirmed a very high efficacy profile in all anatomical scenarios with very low rates of clinically driven TLR and TVR, CV mortality and ST at 3-years.

Для цитирования: Rigatelli Gianluca, Zuin Marco, Gianese Filippo, Adami Dario, dell'Avvocata Fabio, Barison Stefano, Mazza Alberto, Picariello Claudio, Roncon Loris. Ultrathin Biodegradable-Polymer Orsiro Drug-Eluting Stent Performance in Real Practice Challenging Settings.. Cardiovascular revascularization medicine : including molecular interventions. 2020. DOI: 10.1016/j.carrev.2020.09.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.