MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.taap.2015.09.027

Медицинская библиотека · Toxicology and applied pharmacology · 2015

A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers.

Avonto Cristina, Chittiboyina Amar G, Rua Diego, Khan Ikhlas A

Сравнительное исследованиеСтатьяПоддержка правительства СШАПоддержка службы здравоохранения СШАВалидационное исследованиеПеревод в очереди

Аннотация

Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, 'HTS-DCYA assay', is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time.

Для цитирования: Avonto Cristina, Chittiboyina Amar G, Rua Diego, Khan Ikhlas A. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers.. Toxicology and applied pharmacology. 2015. DOI: 10.1016/j.taap.2015.09.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.