MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.gie.2024.09.013

Медицинская библиотека · Gastrointestinal endoscopy · 2024

Technical feasibility of EUS-guided liver abscess drainage for the right hepatic lobe using a novel metal stent as first-line treatment (with video).

Ogura Takeshi, Ueno Saori, Okuda Atsushi, Nishioka Nobu, Sakamoto Jun, Yamada Masanori, Yamamura Masahiro, Uba Yuki, Tomita Mitsuki, Hattori Nobuhiro, Nakamura Junichi, Bessho Kimi, Nishikawa Hiroki

СтатьяVideo-Audio MediaПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: Although EUS-guided liver abscess drainage (EUS-LAD) has been developed, only the left hepatic or caudate lobe can traditionally be drained by EUS. However, there is no evidence for the technical feasibility of EUS-LAD for the right hepatic lobe. In this retrospective study, the technical feasibility of EUS-LAD using a novel partially covered self-expandable metal stent (PCSEMS) with an antimigration system was evaluated as a first-line drainage technique for right hepatic lobe abscesses.

METHODS

This study included consecutive patients with right lobe liver abscesses between December 2020 and February 2024. The primary outcome in this study was the technical success rate of EUS-LAD. Technical success of EUS-LAD was defined as successful stent deployment from the liver abscess to the duodenum. Clinical success, procedure time, duration of hospital stay, recurrence of liver abscess, and adverse events were evaluated as secondary outcomes.

RESULTS

Nineteen patients were enrolled in this study. The location of the liver abscesses was mainly at segment 6. The mean size of the liver abscesses was 91.8 mm. The liver abscess could be identified under EUS guidance from the duodenum in 16 patients. Puncture using a 19-gauge needle was attempted, but the needle could not reach the liver abscess in 1 patient. The novel PCSEMS was successfully deployed in all patients. The technical success rate of EUS-LAD was 78.9% (15/19). Adverse events associated with the procedure were observed in 3 patients, but conservative treatment was successful. Clinical success was obtained in 14 patients (93.3%). The median duration of stent placement was 19 days (range, 7-41). The median follow-up period was 556 days, and recurrence of liver abscess was not observed in any patients.

CONCLUSIONS

EUS-LAD for the right liver lobe using a novel PCSEMS can be feasible and safe.

Для цитирования: Ogura Takeshi, Ueno Saori, Okuda Atsushi, Nishioka Nobu, Sakamoto Jun, Yamada Masanori, Yamamura Masahiro, Uba Yuki, Tomita Mitsuki, Hattori Nobuhiro, Nakamura Junichi, Bessho Kimi, Nishikawa Hiroki. Technical feasibility of EUS-guided liver abscess drainage for the right hepatic lobe using a novel metal stent as first-line treatment (with video).. Gastrointestinal endoscopy. 2024. DOI: 10.1016/j.gie.2024.09.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…