MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.phro.2024.100611

Медицинская библиотека · Physics and imaging in radiation oncology · 2024

Feasibility of simulation free abdominal stereotactic adaptive radiotherapy using an expedited pre-plan workflow.

Price Alex T, Schiff Joshua P, Silberstein Alice, Beckert Robbie, Zhao Tianyu, Hugo Geoffrey D, Samson Pamela P, Laugeman Eric, Henke Lauren E

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Improved hounsfield-unit accuracy of on-board imaging may lead to direct-to-unit treatment approaches We aimed to demonstrate the feasibility of using only a diagnostic (dx) computed tomography (CT)-defined target pre-plan in an in silico study of simulation-free abdominal stereotactic adaptive radiotherapy (ART).

MATERIALS AND

METHODS

Eight patients with abdominal treatment sites (five pancreatic cancer, three oligometastases) were treated using an integrated adaptive O-Ring gantry system. Each patient's target was delineated on a dxCT. The target only pre-plan served primarily to seed the ART process. During the ART session, all structures were delineated. All simulated cases were treated to 50 Gy in 5 fractions to a planning target optimization structure (PTV_OPT) to allow for dose escalation within the planning target volume. Timing of steps during this workflow was recorded. Plan quality was compared between ART treatment plans and a plan created on a CT simulation scan using the traditional planning workflow.

RESULTS

The workflow was feasible in all attempts, with organ-at-risk (OAR) constraints met in all fractions despite lack of initial OAR contours. Median absolute difference between the adapted plan and simulation CT plan for the PTV_Opt V95% was 2.0 %. Median absolute difference in the D0.5 cm3 between the adapted plan and simulation CT plan was -0.9 Gy for stomach, 1.2 Gy for duodenum, -5.3 Gy for small bowel, and 0.3 Gy for large bowel. Median end-to-end workflow time was 63 min.

CONCLUSION

The workflow was feasible for a dxCT-defined target-only pre-plan approach to stereotactic abdominal ART.

Для цитирования: Price Alex T, Schiff Joshua P, Silberstein Alice, Beckert Robbie, Zhao Tianyu, Hugo Geoffrey D, Samson Pamela P, Laugeman Eric, Henke Lauren E. Feasibility of simulation free abdominal stereotactic adaptive radiotherapy using an expedited pre-plan workflow.. Physics and imaging in radiation oncology. 2024. DOI: 10.1016/j.phro.2024.100611.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.