DOI 10.3390/healthcare13162060

Медицинская библиотека · Healthcare (Basel, Switzerland) · 2025

Impact of Volume Control Biosensors on Blood Pressure During Haemodialysis: A Quasi-Experimental Study.

Gimeno-Hernan Veronica, Perez-Ingidua Carla, Rivas-Paterna Ana Belen, Codesal-Sanabria Natividad, Perez-Duque Guillermo, Ascaso-Del-Rio Ana, Ortuño-Soriano Ismael

СтатьяПеревод пока не подготовлен

Аннотация

Background

Intradialytic hypotension is a common complication in haemodialysis, affecting up to 30% of sessions. It results from an imbalance between ultrafiltration and compensatory mechanisms, such as vascular tone and plasma refilling. Volume-controlled biosensors allow for the continuous monitoring of the haemoconcentration, enabling early detection and prevention of hypotension.

Methods

A quasi-experimental study was conducted to assess the effectiveness of biosensors in reducing hypotensive episodes. Two biosensors were compared: the Blood Volume Monitor and the Haemomaster system. Data were collected over two four-month periods: before and after biosensor implementation. Nursing staff received specific training, and a protocol for consistent data collection was established. Informed consent was obtained from all eligible participants. The incidence of intradialytic hypotension was compared between sessions with and without biosensor use. Additionally, outcomes were analysed according to biosensor type.

Results

A total of 2262 dialysis sessions from 22 patients were analysed. The cohort was 54.5% male, with a mean age of 60 years (SE = 21); 27.3% had diabetes and 81.8% had hypertension. Post-dilution haemodiafiltration was performed in 62.8% of sessions. Intradialysis hypotension occurred in 11.2% of sessions using biosensors compared to 14.0% without (p = 0.021). No significant difference was found between biosensor types (10.8% vs. 11.8%; p = 0.531), although device 1 reached a significantly lower critical blood volume (mean: 10 L; SE = 4 vs. 16 L; SE = 5; p = 0.000).

Conclusions

Biosensor use was associated with fewer hypotensive episodes and greater haemodynamic stability. These findings support their integration into routine dialysis practice to improve treatment, safety, and individualised care.

Для цитирования: Gimeno-Hernan Veronica, Perez-Ingidua Carla, Rivas-Paterna Ana Belen, Codesal-Sanabria Natividad, Perez-Duque Guillermo, Ascaso-Del-Rio Ana, Ortuño-Soriano Ismael. Impact of Volume Control Biosensors on Blood Pressure During Haemodialysis: A Quasi-Experimental Study.. Healthcare (Basel, Switzerland). 2025. DOI: 10.3390/healthcare13162060.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.