Accuracy of a Professional Continuous Glucose Monitoring Device in Individuals with Type 2 Diabetes Mellitus.

Nakagawa Yasushi, Hirota Yushi, Yamamoto Akane, Takayoshi Tomofumi, Takeuchi Takehito, Hamaguchi Tetsushi, Matsuoka Atsuko, Sakaguchi Kazuhiko, Ogawa Wataru

СтатьяПеревод пока не подготовлен

Аннотация

Among continuous glucose monitoring (CGM) devices, which continuously measure glucose concentration in subcutaneous interstitial fluid for comprehensive monitoring of blood glucose profile, only FreeStyle Libre Pro® (Abbott Diabetes Care) is currently available in Japan as a professional system. FreeStyle Libre Pro® is easy to use because it does not require calibration by self-monitoring of blood glucose (SMBG), but information on its accuracy has been insufficient. To evaluate the measurement accuracy of FreeStyle Libre Pro®, we have now compared blood glucose levels determined by this device with those measured by SMBG in 40 individuals with type 2 diabetes mellitus. The mean absolute relative difference (MARD) for FreeStyle Libre Pro® measurements compared with SMBG measurements was calculated as an index of CGM accuracy. Overall blood glucose values measured by SMBG were 167.0 ± 60.1 mg/dL, and those determined by FreeStyle Libre Pro® were 155.0 ± 60.7 mg/dL, with this difference being statistically significant. The MARD for FreeStyle Libre Pro® relative to SMBG was 12.7 ± 9.3%. It was substantially higher in 2 of the 40 patients, at 49.2% and 47.5%, than in the other 38 individuals. MARD values did not differ significantly between before and 2 h after meals. However, the MARD was significantly higher for SMBG values of <100 mg/dL than for those of ≥250 mg/dL. Our results thus indicate that the measurement accuracy of FreeStyle Libre Pro® is relatively good, but that some cases in which values determined by the device deviate from SMBG values require caution in interpretation.

Для цитирования: Nakagawa Yasushi, Hirota Yushi, Yamamoto Akane, Takayoshi Tomofumi, Takeuchi Takehito, Hamaguchi Tetsushi, Matsuoka Atsuko, Sakaguchi Kazuhiko, Ogawa Wataru. Accuracy of a Professional Continuous Glucose Monitoring Device in Individuals with Type 2 Diabetes Mellitus.. The Kobe journal of medical sciences. 2022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.