MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vsu.12722

Медицинская библиотека · Veterinary surgery : VS · 2017

Comparison of laparoscopic gastropexy performed via intracorporeal suturing with knotless unidirectional barbed suture using a needle driver versus a roticulated endoscopic suturing device: 30 cases.

Coleman Kristin A, Monnet Eric

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare two suturing techniques for prophylactic laparoscopic gastropexy in healthy dogs.

STUDY

DESIGN

Retrospective case series.

ANIMALS: Thirty healthy client-owned dogs from breeds predisposed to gastric dilation volvulus.

METHODS

Medical records of dogs presented for prophylactic laparoscopic gastropexy performed with knotless unidirectional barbed suture were reviewed. Dogs were grouped based on the device used for suturing, consisting of an endoscopic needle driver (END) vs an endoscopic suturing device (ESD). Signalment, weight, surgery time, number of suture bites per side of gastropexy, and intraoperative complications were compared between groups.

RESULTS

The END group consisted of 10 dogs, with a median age of 1.09 years (range 0.5-2.67), weight of 41.5 kg (range 25-66), surgical time of 49.5 minutes (range 35-77), and a median of 5 suture bites per side (range 4-6). The ESD group included 20 dogs, with a median age of 1.75 years (range 0.6-8.75, P = .0944), weight was 37.5 kg (range 20-62, P = .5823), surgical time of 55 minutes (range 30-76, P = .808), and a median of 6 suture bites for the first side (range 4-7, P = .072) and 7 for the second side (range 4-8, P = .003). No major complications and no conversion to open celiotomy occured in either group. Minor complications occurred in 3 dogs in the ESD group, all related to device dysfunction and suture breakage.

CONCLUSION

Laparoscopic gastropexy may be performed effectively with either of these suturing techniques.

Для цитирования: Coleman Kristin A, Monnet Eric. Comparison of laparoscopic gastropexy performed via intracorporeal suturing with knotless unidirectional barbed suture using a needle driver versus a roticulated endoscopic suturing device: 30 cases.. Veterinary surgery : VS. 2017. DOI: 10.1111/vsu.12722.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.