MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0035-1545664

Медицинская библиотека · American journal of perinatology · 2015

Ultrasonographic Fetal Weight Estimation: Should Macrosomia-Specific Formulas Be Utilized?

Porter Blake, Neely Cherry, Szychowski Jeff, Owen John

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study aims to derive an estimated fetal weight (EFW) formula in macrosomic fetuses, compare its accuracy to the 1986 Hadlock IV formula, and assess whether including maternal diabetes (MDM) improves estimation.

STUDY

DESIGN

Retrospective review of nonanomalous live-born singletons with birth weight (BWT) ≥ 4 kg and biometry within 14 days of birth. Formula accuracy included: (1) mean error (ME = EFW - BWT), (2) absolute mean error (AME = absolute value of [1]), and (3) mean percent error (MPE, [1]/BWT × 100%). Using loge BWT as the dependent variable, multivariable linear regression produced a macrosomic-specific formula in a "training" dataset which was verified by "validation" data. Formulas specific for MDM were also developed.

RESULTS

Out of the 403 pregnancies, birth gestational age was 39.5 ± 1.4 weeks, and median BWT was 4,240 g. The macrosomic formula from the training data (n = 201) had associated ME = 54 ± 284 g, AME = 234 ± 167 g, and MPE = 1.6 ± 6.2%; evaluation in the validation dataset (n = 202) showed similar errors. The Hadlock formula had associated ME = -369 ± 422 g, AME = 451 ± 332 g, MPE = -8.3 ± 9.3% (all p < 0.0001). Diabetes-specific formula errors were similar to the macrosomic formula errors (all p = NS).

CONCLUSIONS

With BWT ≥ 4 kg, the macrosomic formula was significantly more accurate than Hadlock IV, which systematically underestimates fetal/BWT. Diabetes-specific formulas did not improve accuracy. A specific formula should be considered when macrosomia is suspected.

Для цитирования: Porter Blake, Neely Cherry, Szychowski Jeff, Owen John. Ultrasonographic Fetal Weight Estimation: Should Macrosomia-Specific Formulas Be Utilized?. American journal of perinatology. 2015. DOI: 10.1055/s-0035-1545664.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.