MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.surneu.2004.09.042

Медицинская библиотека · Surgical neurology · 2005

Poor surgical technique in cervical plating leading to vertebral artery injury and brain stem infarction--case report.

Cho Ki Hong, Shin Yong Sam, Yoon Soo Han, Kim Se Hyuk, Ahn Young Hwan, Cho Kyung Gi

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Lateral mass plating is a safe fixating system for lower cervical fractures. Brain stem infarction after cervical lateral mass screw plating has not been reported in previous literature. We report a case of poor surgical technique leading to vertebral artery injury and brain stem infarction after cervical lateral mass plating.

CASE DESCRIPTION: A 41-year-old male patient was transferred to our hospital because of hemiparesis and dysarthria immediately after lateral mass plating for fracture and dislocation of the fifth and sixth cervical vertebrae. Brain magnetic resonance imaging showed infarction of the left posterior inferior cerebellar artery territory, and the vertebral artery angiography showed complete occlusion of the left vertebral artery. The cervical computed tomography revealed a left screw of the fifth and sixth cervical vertebrae penetrating the central portion of the transverse foramen. The patient was managed with anticoagulant and supportive therapy only, with subsequent improvement of hemiparesis and dysarthria.

CONCLUSIONS

Poor surgical technique of lateral mass plating in the cervical spine could lead to vertebral artery injury and even brain stem infarction. Postoperative brain infarction in cervical fusion could be a complication of the usually safe lateral mass plating of the cervical spine.

Для цитирования: Cho Ki Hong, Shin Yong Sam, Yoon Soo Han, Kim Se Hyuk, Ahn Young Hwan, Cho Kyung Gi. Poor surgical technique in cervical plating leading to vertebral artery injury and brain stem infarction--case report.. Surgical neurology. 2005. DOI: 10.1016/j.surneu.2004.09.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.