Right atrial preventive and antitachycardia pacing for prevention of paroxysmal atrial fibrillation in patients without bradycardia: a randomized study.

Hemels Martin E W, Ruiter Jaap H, Molhoek G Peter, Veeger Nic J G M, Wiesfeld Ans C P, Ranchor Adelita V, van Trigt Marcel, Pilmeyer Art, Van Gelder Isabelle C, Features in AT500TM Study, Chances for Patients with Episodes of Atrial Tachyarrhythmia without Bradycardia Indication for Pacing (FACET) Investigators

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: To investigate the efficacy of preventive and antitachycardia pacing (ATP) in patients with symptomatic paroxysmal atrial fibrillation (AF) without bradyarrhythmias.

METHODS AND

RESULTS

In this randomized cross-over pilot study, we randomized 38 symptomatic paroxysmal AF patients 'without' bradyarrhythmias to atrial pacing lower rate 70 ppm and prevention and ATP therapies ON or to atrial pacing lower rate 34 ppm and prevention and ATP therapies OFF during 12 weeks with a 4 week washout period in between. The atrial lead was preferably placed in the inter-atrial septum. Antiarrhythmic drugs were continued during the study. Primary endpoint was AF burden. Mean age was 62 +/- 9 years and 27 (71%) patients had lone AF. Septal lead placement was accomplished in 26 (68%) patients. During the treatment ON, there was a trend for AF burden reduction [from median 3.3% (1.0-15.2) to 2.4% (0.2-12.2), P = 0.06, reduction 27%]. If septal lead placement was accomplished, AF burden reduction was statistically significant [44% reduction, from median 2.5% (1.0-8.0) to 1.4% (0.2-8.4), P = 0.03]. Quality of life and symptoms did not change, also not in the septal group.

CONCLUSION

A hybrid therapy of preventive and ATP pacing and antiarrhythmic drugs may significantly reduce but not abolish AF burden if septal pacing is realized.

Для цитирования: Hemels Martin E W, Ruiter Jaap H, Molhoek G Peter, Veeger Nic J G M, Wiesfeld Ans C P, Ranchor Adelita V, van Trigt Marcel, Pilmeyer Art, Van Gelder Isabelle C, Features in AT500TM Study, Chances for Patients with Episodes of Atrial Tachyarrhythmia without Bradycardia Indication for Pacing (FACET) Investigators. Right atrial preventive and antitachycardia pacing for prevention of paroxysmal atrial fibrillation in patients without bradycardia: a randomized study.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2008. DOI: 10.1093/europace/eum301.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.