MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/eurheartj/ehm227

Медицинская библиотека · European heart journal · 2007

Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome.

Van Belle Yves, Janse Petter, Rivero-Ayerza Maximo J, Thornton Andrew S, Jessurun Emile R, Theuns Dominic, Jordaens Luc

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIMS: To assess safety, feasibility and short term outcome of pulmonary vein (PV) isolation in paroxysmal atrial fibrillation (AF) with a cryoballoon.

METHODS

We consecutively treated 57 patients with a double lumen 23 or 28 mm cryoballoon. The acute results, complications and follow-up over the first three months were analysed, using a comprehensive and intensive follow-up period.

RESULTS

During 57 procedures, 185 of 220 targeted PV's were successfully isolated using the cryoballoon (84%) (balloon group, 33 patients). In 33 veins (15%) an additional segmental isolation (hybrid group, 24 patients) was necessary with a standard cryocatheter to achieve isolation. The average procedure times were respectively 211 +/- 108 and 261 +/- 83 minutes (NS), the average fluoroscopy times 52 +/- 36 and 66 +/- 33 minutes (NS). The number of balloon applications did not differ between both groups: respectively a median 9 (4-18) and 10 (5-17) (NS). We observed four phrenic nerve paralysis after ablation of the right superior PV: two resolved immediately after cessation of the cryoenergy, one recovered after 3 months, one persisted up to 6 months. A daily transtelephonic rhythm recording showed a significant drop in mean AF burden from 24% to 10%, 8% and 5% during the three consecutive months of follow-up (p < 0.01 versus baseline). No differences were observed between the treatment groups. 34 patients (60%) were completely free from AF after a single procedure.

CONCLUSIONS

Balloon cryoablation of the pulmonary veins with additional segmental isolation if necessary, is a good approach for patients presenting with paroxysmal AF, showing a significant reduction in AF burden after a single procedure. The major complication seems to be phrenic nerve paralysis after ablation of the right superior PV, but this is potentially reversible over several months.

Для цитирования: Van Belle Yves, Janse Petter, Rivero-Ayerza Maximo J, Thornton Andrew S, Jessurun Emile R, Theuns Dominic, Jordaens Luc. Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome.. European heart journal. 2007. DOI: 10.1093/eurheartj/ehm227.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.