[MRI of the small intestine with rapid MRI sequences in Crohn disease after enteroclysis with oral iron particles].

Holzknecht N, Helmberger T, von Ritter C, Gauger J, Faber S, Reiser M

Сравнительное исследованиеАннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the efficacy of breathhold MRI following enteroclysis with addition of oral magnetic particles to study the extension, detection of stenoses and extraluminal manifestations in Crohn's disease.

MATERIAL AND

METHODS

18 patients with Crohn's disease and potential of surgical intervention were studied with enteroclysis with addition of oral magnetic particles. T1-/T2-weighted breathhold MRI w/o spectral fat suppression w/o i.v. Gd-DTPA was applied.

RESULTS

Typical findings were marked bowel wall thickening with strong contrast enhancement. 95.8% of affected small bowel segments and 94.7% of stenoses were correctly detected by MRI. All four fistulas were detected and important extraluminal findings were seen in 6/18 patients. Additionally, one ileoileal and two ileosigmoidal adhesions, two extraluminal abscesses and affection of the right ureter were delineated.

CONCLUSION

MRI in Crohn's disease offers the potential to avoid radiation exposure in this relatively young patient group. Important additional findings relevant to indication of surgery are seen in approximately one third of cases. The replacement of transduodenal intubation by oral contrast application remains to be further studied.

Для цитирования: Holzknecht N, Helmberger T, von Ritter C, Gauger J, Faber S, Reiser M. [MRI of the small intestine with rapid MRI sequences in Crohn disease after enteroclysis with oral iron particles].. Der Radiologe. 1998. DOI: 10.1007/s001170050320.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.