MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10047-017-0988-z

Медицинская библиотека · Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2017

Outcomes in patients with advanced heart failure and small body size undergoing continuous-flow left ventricular assist device implantation.

Volkovicher Nastasya, Kurihara Chitaru, Critsinelis Andre, Kawabori Masashi, Sugiura Tadahisa, Manon Marcos, Civitello Andrew B, Morgan Jeffrey A

СтатьяПеревод пока не подготовлен

Аннотация

Left ventricular assist devices (LVADs) have become a preferred treatment option for patients with end-stage heart failure when used as a bridge to transplant or as a destination therapy. However, the association between small body size and postoperative outcomes for continuous-flow (CF) LVAD recipients is still being studied. We sought to determine whether body surface area (BSA) is associated with patient outcomes after CF-LVAD implantation. The study cohort of our single-center, retrospective review consisted of all patients (n = 526) who underwent CF-LVAD implantation (n = 403 HeartMate II, n = 123 HeartWare) between November 2003 and March 2016 regardless of indication. Patients were stratified into 2 cohorts according to their BSA measurements: small BSA (<1.5 m2, n = 13) and non-small BSA (≥1.5 m2, n = 513). We compared the survival of the small-BSA cohort with that of the non-small-BSA cohort. Patients with a small BSA had lower survival rates at 1, 6, 12, and 24 months (76.9, 61.5, 53.8, and 38.5%, respectively) than did patients with a non-small BSA (90.4, 80.9, 74.7, and 67.6% respectively; overall, p = 0.004). Cox proportional hazard analysis showed that a small BSA was an independent predictor of postoperative mortality (hazard ratio = 0.22, 95% confidence interval = 0.05-0.97, p < 0.04). These findings highlight the adverse impact of a small BSA on outcomes after CF-LVAD implantation.

Для цитирования: Volkovicher Nastasya, Kurihara Chitaru, Critsinelis Andre, Kawabori Masashi, Sugiura Tadahisa, Manon Marcos, Civitello Andrew B, Morgan Jeffrey A. Outcomes in patients with advanced heart failure and small body size undergoing continuous-flow left ventricular assist device implantation.. Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs. 2017. DOI: 10.1007/s10047-017-0988-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.