MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00004728-199907000-00020

Медицинская библиотека · Journal of computer assisted tomography · 1999

Carotid bifurcation CT angiography: assessment of interactive volume rendering.

Verhoek G, Costello P, Khoo E W, Wu R, Kat E, Fitridge R A

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was to compare the accuracy of CT angiography (CTA) for the assessment of carotid bifurcation stenosis, using interactive volume rendering (VR), maximum intensity projection (MIP), and 2D transverse CT technique (t-CT).

METHOD: Nineteen consecutive patients were prospectively studied with CTA and selective digital subtraction angiography (DSA). There were 13 men and 6 women from 51 to 84 years old (mean 70 years). Results of DSA were compared with those of interactive VR, MIP, and conventional t-CT results, using North American Symptomatic Carotid Endarterectomy Trial criteria for stenosis grading.

RESULTS

There were a total of 38 carotid bifurcations studied, with 9 mild, 10 moderate, and 15 severe stenoses and 4 occlusions. Overall agreement with DSA for VR was achieved in 76%. Eighty percent of the severe stenoses were correctly predicted by VR. The overall agreement between t-CT and DSA was 89%. MIP images, when analyzed independently, showed an overall agreement with angiography of only 71%. VR was not significantly different from MIP (p = 0.60). The difference between VR and t-CT had borderline significance (p = 0.09). MIP had significantly poorer agreement with angiography than t-CT (p = 0.02).

CONCLUSION

CTA has a high degree of accuracy for the assessment of carotid artery disease compared with catheter angiography. Interactive VR increases the accuracy of diagnosing carotid stenosis and decreases the number of unsatisfactory studies as compared with MIP. Further advances in computation speeds and improvements in software may dramatically alter the future use of VR for the communication of results to clinicians; however, careful analysis of transverse sections is essential to accurate CT interpretation.

Для цитирования: Verhoek G, Costello P, Khoo E W, Wu R, Kat E, Fitridge R A. Carotid bifurcation CT angiography: assessment of interactive volume rendering.. Journal of computer assisted tomography. 1999. DOI: 10.1097/00004728-199907000-00020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.