MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.otohns.2004.11.008

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2005

Endoscopic management of cerebrospinal fluid leak associated with the use of bone wax in skull-base surgery.

Bolger William E, Tadros Monica, Ellenbogen Richard G, Judy Kevin, Grady M Sean

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To alert otolaryngologists to consider the possibility that bone wax may be associated with cerebrospinal fluid leaks that occur immediately after skull-base craniotomy approaches.

STUDY DESIGN AND

SETTING

Clinical report from surgical experience in a tertiary care setting.

RESULTS

Three patients presented with brisk cerebrospinal fluid leak after craniotomy. Sinus endoscopy revealed bone wax within a small parasphenoid defect in all 3 cases.

CONCLUSIONS

Bleeding from areas of the skull base adjacent to the paranasal sinuses during craniotomy can signal a small breach of the skull base. Bone wax may control bleeding from edges of transected bone but also stent the skull-base defect open, preventing fibrin deposition and spontaneous healing and closure.

SIGNIFICANCE: Otolaryngologists repairing a cerebrospinal fluid leak after a skull-base craniotomy approach should consider the possibility of encountering bone wax and be able to identify it to better treat their patient.

Для цитирования: Bolger William E, Tadros Monica, Ellenbogen Richard G, Judy Kevin, Grady M Sean. Endoscopic management of cerebrospinal fluid leak associated with the use of bone wax in skull-base surgery.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2005. DOI: 10.1016/j.otohns.2004.11.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.