MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41440-023-01540-3

Медицинская библиотека · Hypertension research : official journal of the Japanese Society of Hypertension · 2024

The feasibility, efficacy, and safety of RDN procedure using CO2 angiography through radial artery in severe chronic kidney disease patients.

Lo Hao-Yun, Lee Jen-Kuang, Lin Yen-Hung

Наблюдательное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The recent evidence regarding the effectiveness of renal denervation (RDN) in blood pressure control is becoming increasingly substantial. However, many studies have excluded populations with severely impaired kidney function, even though these individuals have a higher prevalence of hypertension compared to the general population, and controlling their blood pressure is more challenging. The effectiveness and safety of RDN in patients with severe chronic kidney disease (CKD) lack strong evidence support. Concerns about worsening kidney function still exist, particularly in patients with CKD stage 5. We conducted an observational study involving 10 patients who were using at least 3 different antihypertensive medications and had an estimated glomerular filtration rate (eGFR) < 45 mL/min/1.73 m2 but had not undergone dialysis. For these patients, we performed RDN via the radial artery approach, with the assistance of carbon dioxide (CO2) angiography. Utilizing this approach, the systolic 24-hour ambulatory blood pressure monitoring did not exhibit a significant decrease at 3 months; however, a significant reduction was observed at 6 months after RDN. We also minimized contrast agent usage, observed no kidney function decline 3 months post-RDN, and experienced no vascular-related complications. Using the radial artery approach and CO2 angiography assistance for RDN may be an effective and safe blood pressure control method for patients with severe kidney impairment.

Для цитирования: Lo Hao-Yun, Lee Jen-Kuang, Lin Yen-Hung. The feasibility, efficacy, and safety of RDN procedure using CO2 angiography through radial artery in severe chronic kidney disease patients.. Hypertension research : official journal of the Japanese Society of Hypertension. 2024. DOI: 10.1038/s41440-023-01540-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.