DOI 10.1016/j.avsg.2024.07.114

Медицинская библиотека · Annals of vascular surgery · 2024

Comparison of the Novel Ankura Plus Stent and Castor Stent for the Treatment of Stanford Type B Aortic Dissection with an Insufficient Proximal Anchoring Area.

Liu Boyu, Zhang Like, Liu Peng, Wang Zibin, Wang Boyu, Zhang Lei

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

To compare the efficacy and safety of the Ankura Plus and Castor stents in Stanford type B aortic dissection (TBAD) with an insufficient proximal anchoring area.

METHODS

Between January 2020 and October 2022, 54 patients with TBAD were enrolled, including 16 patients with Ankura Plus stents and 38 patients with Castor stents. Data from the 2 stents were retrospectively analyzed.

RESULTS

The surgical success rate for both stents was 100%, and no endoleaks or deaths occurred during hospitalization. The Ankura Plus stent group had a longer surgery time than the Castor stent group (122.6 ± 5.1 vs. 103.7 ± 10.0, P < 0.001). After an average follow-up of 12 months, the patency rates of the main and branch stents were 100% in both groups. The diameter of the true lumen (TL) was significantly increased, the diameter of the false lumen (FL) was reduced, and there was no statistically significant difference in the probability of complete thrombosis of the FL (68.8% vs. 67.6%, P = 0.993). There were no significant differences in the incidences of renal failure (6.3% vs. 8.1%, P = 0.814), stroke (6.3% vs. 2.7%, P = 0.520), or endoleaks (6.3% vs. 10.5%, P = 0.621) between the Ankura Plus and Castor stent groups. One patient in the Castor stent group underwent reintervention because of a type I endoleak 3 months after surgery. One patient in the Ankura Plus stent group had an additional covered stent placed after 1 month due to distal TL stenosis of the main stent. One patient in the Castor stent group died of renal failure 4 months after surgery.

CONCLUSIONS

Both the Ankura Plus and Castor stents are feasible, safe, and effective in the treatment of TBAD with an insufficient proximal anchoring area. Additional long-term studies are required to evaluate the robustness and applicability of Ankura Plus stents.

Для цитирования: Liu Boyu, Zhang Like, Liu Peng, Wang Zibin, Wang Boyu, Zhang Lei. Comparison of the Novel Ankura Plus Stent and Castor Stent for the Treatment of Stanford Type B Aortic Dissection with an Insufficient Proximal Anchoring Area.. Annals of vascular surgery. 2024. DOI: 10.1016/j.avsg.2024.07.114.