A morphological indicator for aortic dissection: fitting circle of the thoracic aorta.

Pu Hongji, Peng Tao, Xu Zhijue, Sun Qi, Wang Zixin, Ma Hui, Fang Shu, Yang Yang, Wu Jie, Wang Ruihua, Qiu Peng, Zhou Jinhua, Lu Xinwu

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

This study aims to identify a morphological indicator of aortic dissection (AD) based on the geometrical characteristics of the thoracic aorta.

METHODS

We evaluated computed tomographic angiograms of 63 samples with AD (22 with type A AD, 41 with type B AD) and 71 healthy samples. Via centerline extraction and spatial transformation, the spatial entanglement of the aorta was minimized, and the expanded 2D aortic morphology was obtained. The 2D morphology of the thoracic aorta was fit to a circle. The applicability of the fitting circle method for identifying aortic dissection was verified by multivariable logistic regression analysis.

RESULTS

Via the 3D coordinate transformation algorithm, the optimal aortic view was obtained. On this view, the geometrical characteristics of the thoracic aortas of the healthy controls were similar to a portion of a circle (sum of residuals: 3502.45 ± 2566.71, variance: 86.23 ± 56.60), while that of AD samples had poorer similarity to the circle (sum of residuals: 5404.78 ± 3891.69, variance: 129.90 ± 90.09). This difference was significant (p < 0.001). A logistic regression model showed that increased deformation of the thoracic aorta was a significant indicator of aortic dissection (odds ratio: 1.35, p = 0.034).

CONCLUSIONS

The morphology of the healthy thoracic aorta could be fit to a circle, while that of the dissected aorta had poorer similarity to the circle. The statistics of the circle are an effective indicator of aortic deformation in AD.

TRIAL REGISTRATION: This study is registered in the Chinese Clinical Trial Registry (ChiCTR2000029219).

Для цитирования: Pu Hongji, Peng Tao, Xu Zhijue, Sun Qi, Wang Zixin, Ma Hui, Fang Shu, Yang Yang, Wu Jie, Wang Ruihua, Qiu Peng, Zhou Jinhua, Lu Xinwu. A morphological indicator for aortic dissection: fitting circle of the thoracic aorta.. BMC cardiovascular disorders. 2024. DOI: 10.1186/s12872-024-04130-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.