MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00270-020-02749-2

Медицинская библиотека · Cardiovascular and interventional radiology · 2021

Technique-Based Evaluation of Clinical Outcomes and Aortic Remodelling Following TEVAR in Acute and Subacute Type B Aortic Dissection.

Zhong Jim, Osman Ahmed, Tingerides Costa, Puppala Sapna, Shaw David, McPherson Simon, Darwood Rosemary, Walker Paul

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

To evaluate the clinical outcomes and aortic remodelling rates following thoracic endovascular aortic repair (TEVAR) for acute or subacute type B aortic dissection (TBAD) based on technique.

MATERIAL AND

METHODS

All TEVARs for acute/subacute TBAD between 01/01/2008 and 01/06/2020 were included. TEVARS were grouped by technique (TEVAR only, PETTICOAT and STABILISE). Aortic remodelling was assessed at three aortic levels on follow-up CT. Thirty-day technical/clinical success rates, re-intervention rates and complications were recorded.

RESULTS

A total of 29 patients were included. The median age was 55 years (31-82). The median duration from initial presentation to TEVAR was 7 days (0-84). Intra-procedural complications included one aortic rupture from balloon moulding in a STABILISE case. Thirty-day mortality, stroke, spinal cord ischaemia and visceral ischaemia were 3% (n = 1), 3% (n = 1), 3% (n = 1) and 3% (n = 1), respectively. (All occurred in acute TBAD.) Overall survival was 50.5 months (18-115). Median follow-up was 31 months (1-115). Six patients (21%) required re-intervention, with a median time of 5 months (5-46) from first TEVAR. Overall complete aortic remodelling rates were: 89% at the proximal descending thoracic aorta, 78% at the distal thoracic aorta and 50% at the infra-renal abdominal aorta. At the infra-renal aorta, the STABILISE group (n = 11) had a higher complete aortic remodelling rate (82%) compared to TEVAR alone (n = 12) (20%).

CONCLUSION

Endovascular intervention for acute and subacute TBAD is safe with a high rate of technical success. STABILISE results in higher aortic remodelling at the infra-renal aorta (82%) compared to TEVAR alone (20%) but risks aortic rupture from balloon moulding.

Для цитирования: Zhong Jim, Osman Ahmed, Tingerides Costa, Puppala Sapna, Shaw David, McPherson Simon, Darwood Rosemary, Walker Paul. Technique-Based Evaluation of Clinical Outcomes and Aortic Remodelling Following TEVAR in Acute and Subacute Type B Aortic Dissection.. Cardiovascular and interventional radiology. 2021. DOI: 10.1007/s00270-020-02749-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.