BACKGROUND

Echocardiographic reference intervals for Friesian horses are poorly described.

OBJECTIVES

To obtain reference intervals for echocardiographic measurements in Friesians and compare these with Warmbloods.

ANIMALS: One hundred healthy adult Friesians and 100 healthy adult Warmblood horses.

METHODS

Cross-sectional study. Two-dimensional and M-mode echocardiographic images were obtained. Echocardiographic measurements, including size, area, and volumetric measurements of left atrium, left and right ventricle, aorta, and pulmonary artery, were performed. Measurements were compared between the 2 breeds using an independent samples t test with Bonferroni correction for multiple comparisons.

RESULTS

Reference ranges for standard echocardiographic measurements in Friesians were obtained. Several left ventricular measurements were significantly smaller in Friesians compared to Warmbloods, such as the left ventricular end-diastolic volume using the 4-chamber modified Simpsons' method (99.85% confidence interval for the difference [CI] = -245 to -63). Also the right ventricular end-diastolic and peak-systolic internal diameter were smaller in Friesians (99.85% CI = -1.33 to -0.6 and 99.85% CI = -1.54 to -0.76, respectively). Fractional shortening (99.85% CI = 0.61-6) and ejection fraction (99.85% CI = 0.21-4.6) were significantly larger. No structural effects of systemic hypertension, such as concentric hypertrophy, were detected.

CONCLUSIONS AND CLINICAL

IMPORTANCE

Our study provides reference intervals for echocardiographic measurements in Friesians useful in a clinical setting. In general, the left ventricular dimensions in Friesians were significantly smaller compared to Warmbloods, emphasizing the need for breed-specific reference intervals.

Для цитирования: Vernemmen Ingrid, Vera Lisse, Van Steenkiste Glenn, van Loon Gunther, Decloedt Annelies. Reference values for 2-dimensional and M-mode echocardiography in Friesian and Warmblood horses.. Journal of veterinary internal medicine. 2020. DOI: 10.1111/jvim.15938.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.