MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00129492-200409000-00013

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2004

Late failure of cochlear implantation resulting from advanced cochlear otosclerosis: surgical and programming challenges.

Toung James S, Zwolan Teresa, Spooner Thomas R, Telian Steven A

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVE

The objective of this study was to discuss cochlear implantation in the setting of severe cochlear otosclerosis and review programming challenges in a patient whose performance is deteriorating as a result of advancing disease.

STUDY

DESIGN

We conducted a case report and literature review.

SETTING

Tertiary care medical center. PATIENTS, INTERVENTION, AND

RESULTS

A case is presented of a 66-year-old man with otosclerosis who initially had good benefit from a cochlear implant but gradually lost benefit even with reimplantation. Imaging studies demonstrated severely distorted otic capsule anatomy from cochlear otosclerosis.

CONCLUSIONS

Advancing cochlear otosclerosis can result in a severely thinned and distorted otic capsule. Although cochlear implantation is generally beneficial in cochlear otosclerosis, implantation in certain severe cases may be complicated as a result of difficulties with cerebrospinal fluid leak, programming challenges, and other potential hazards that can occur with a distorted anatomy.

Для цитирования: Toung James S, Zwolan Teresa, Spooner Thomas R, Telian Steven A. Late failure of cochlear implantation resulting from advanced cochlear otosclerosis: surgical and programming challenges.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2004. DOI: 10.1097/00129492-200409000-00013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.