Stent Graft Sizing for Endovascular Abdominal Aneurysm Repair Using Open Source Image Processing Software.

Knöps Eva, van Schaik Jan, van der Bogt Koen E A, Veger Hugo T C, Putter Hein, Waasdorp Evert J, van der Vorst Joost R

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

An important step to reach a favorable outcome of abdominal endovascular aneurysm repair (EVAR) is preoperative sizing of the stent graft using computed tomography angiography (CTA) images of the abdominal aorta. A variety of costly image processing software options is available to obtain the necessary aortic measurements. A package that can be used for EVAR sizing is OsiriX Lite®-an open source, freely downloadable image processing option. This study assesses the concurrent validity of OsiriX Lite® when compared with commercially available 3Mensio Vascular® and Siemens Syngo.via®.

METHODS

CTA scans of 20 patients that underwent EVAR for abdominal aneurysm were selected, 10 elective and 10 ruptured. For each scan, 6 observers determined 20 parameters needed for proper stent graft sizing, 2 using Osirix Lite®, 3 using 3Mensio Vascular®, and 1 using Siemens Syngo.via®. For each parameter, an intraclass correlation coefficient (ICC) and a P-value were calculated. Interrater agreement was interpreted using the Koo and Li Guidelines. Time needed to perform EVAR planning was compared.

RESULTS

Overall interrater agreement between the 3 sizing options was found to be either "good" or "moderate" for 16 out of 20 parameters (80%). Time needed to perform EVAR planning was not significantly different for Osirix Lite® (568 sec) when compared with 3Mensio Vascular® (603 sec) or Siemens Syngo.via® (659 sec) with a P-value of 0.88.

CONCLUSIONS

The authors conclude that Osirix Lite® is an accurate and time-effective image processing option for preoperative sizing of an EVAR stent graft when matched to 3Mensio Vascular® and Siemens Syngo.via®.

Для цитирования: Knöps Eva, van Schaik Jan, van der Bogt Koen E A, Veger Hugo T C, Putter Hein, Waasdorp Evert J, van der Vorst Joost R. Stent Graft Sizing for Endovascular Abdominal Aneurysm Repair Using Open Source Image Processing Software.. Annals of vascular surgery. 2020. DOI: 10.1016/j.avsg.2020.08.126.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.