Ultrasound assessment of short peripheral catheter failure.

Giustivi Davide, Celano Rosita, Cattalani Manuela, Camilli Claudia, Trombetta Lucia, Facchinetti Pietro, Bartoli Arianna, Bizzi Emanuele, Urso Francesco, Donadoni Mattia, Quici Massimiliano, La Cava Leyla, Calloni Maria, Martini Elena, Taino Alba, Cogliati Chiara, Gidaro Antonio

СтатьяНаблюдательное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

Short peripheral catheters (SPCs) are affected by a high complication rate that leads to catheter failure. Currently, the Visual Infusion Phlebitis score (VIP) is the most used tool to verify the presence of inflammatory complications (phlebitis and thrombophlebitis). However, ultrasound signs (US) may be an attractive alternative.

OBJECTIVE

This study aims to evaluate the sensitivity and specificity of US and VIP score = 1 in identifying and recognizing early signs of SPC failure. The time to positivity for US and VIP scores was assessed as a secondary outcome.

METHODS

An observational prospective study was conducted. In each patient, US (subcutaneous edema; fibroblastic sleeve; thrombophlebitis) and VIP of the exit site were performed every 24 h until 96 h after insertion. Compared to catheter failure, Sensitivity, Specificity, and Predictive values in both US and VIP were calculated.

RESULTS

Two hundred patients were enrolled. The presence of ultrasonic pattern suggestive of edema at 72 h (p = 0.018), fibroblastic sleeve at 24, 48, 72, and 96 h (p < 0.001), thrombosis at 48 (p < 0.001) and 72 h (p = 0.005), and at least one of an abovementioned US at all checkpoints (p < 0.001) were highly significant predictors of complications. Both US and VIP effectively detect inflammatory events; however, the US showed better sensitivity in overall checkpoints and earlier predictive ability than VIP (1.9 vs 0.47 days).

CONCLUSIONS

An ultrasound inflammatory pattern is correlated with SPC failure. An ultrasound protocol-requiring minimal training-is more effective than VIP in recognizing early signs of device failure.

Для цитирования: Giustivi Davide, Celano Rosita, Cattalani Manuela, Camilli Claudia, Trombetta Lucia, Facchinetti Pietro, Bartoli Arianna, Bizzi Emanuele, Urso Francesco, Donadoni Mattia, Quici Massimiliano, La Cava Leyla, Calloni Maria, Martini Elena, Taino Alba, Cogliati Chiara, Gidaro Antonio. Ultrasound assessment of short peripheral catheter failure.. The journal of vascular access. 2024. DOI: 10.1177/11297298241261146.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.