Hand Acceleration Time is a Valuable Ultrasonographic Tool in Hand Perfusion as Adjuvant Evaluation for Diagnosing Chronic Upper Limb Ischemia.

Gonzalo Begoña, Videla Sebastián, Moranas José, Carnaval Thiago, Herranz Carolina, Espinar Emma, Iborra Elena

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Diagnosis of chronic upper limb ischemia is mainly clinical. Although hand perfusion can be evaluated by different noninvasive methods (e.g., digital-brachial index, digital pressures, oxygen saturation measurements, and plethysmography), these have not been standardized for the diagnosis of chronic upper limb ischemia. Initial reports suggested that the hand acceleration time (HAT) measured by duplex ultrasound could be a useful diagnostic tool. However, the HAT has neither been properly characterized nor validated. This study aimed to provide evidence that HAT is a sensitive diagnostic tool for chronic upper limb ischemia.

METHODS

We conducted a prospective, single-center, cross-sectional study with adult patients diagnosed with chronic upper limb ischemia and healthy adult volunteers without cardiovascular risk factors. Hand vascular duplex ultrasound and HAT measurement were performed in 4 artery locations: princeps pollicis artery, radialis indicis artery, first common digital palmar artery, and third common digital palmar artery. It was also measured in the ulnar and radial arteries. Descriptive and exploratory analyses were performed between patients and healthy volunteers.

RESULTS

Thirty participants were included, being 15 patients (median [standard deviation] age: 51 [18] years; 47% women) and 15 healthy volunteers (median [standard deviation] age: 35 [10] years; 60% women). In total, 15 ischemic and 30 nonischemic hands were analyzed. Humeral artery stenosis/occlusion (n = 6, 40.0%) and distal artery stenosis (n = 5, 33.3%) were the main causes of ischemia. Median (interquartile range) HAT measurements were significantly different between patients and healthy volunteers in the 4 hand arterial locations, the radial artery, and ulnar artery: princeps pollicis artery: 164 (124-252) vs. 60 (40-88), P < 0.001; radialis indicis artery: 176 (140-348) vs. 60 (36-80), P < 0.001; first common digital palmar artery: 180 (92-320) vs. 64 (36-88), P < 0.001; third common digital palmar artery: 180 (104-240) vs. 56 (44-92), P < 0.001; radial artery: 156 (120-248) vs. 68 (55-76), P < 0.001; and ulnar artery: 152 (76-220) vs. 61 (48-76), P < 0.001.

CONCLUSIONS

Vascular duplex ultrasound with HAT measurement seems to be an easy-access, sensitive diagnostic tool for chronic upper limb ischemia. HAT provides valuable information on hand perfusion and may be complementary to current noninvasive methods.

Для цитирования: Gonzalo Begoña, Videla Sebastián, Moranas José, Carnaval Thiago, Herranz Carolina, Espinar Emma, Iborra Elena. Hand Acceleration Time is a Valuable Ultrasonographic Tool in Hand Perfusion as Adjuvant Evaluation for Diagnosing Chronic Upper Limb Ischemia.. Annals of vascular surgery. 2024. DOI: 10.1016/j.avsg.2024.05.045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.