m+Medelevator.RU
← Поиск публикаций
PloS one · 2015

Release of Intracoronary Microparticles during Stent Implantation into Stable Atherosclerotic Lesions under Protection with an Aspiration Device.

Клиническое исследованиеСравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Horn Patrick, Baars Theodor, Kahlert Philipp, Heiss Christian, Westenfeld Ralf, Kelm Malte, Erbel Raimund, Heusch Gerd, Kleinbongard Petra

Аннотация

OBJECTIVE: Stent implantation into atherosclerotic coronary vessels impacts on downstream microvascular function and induces the release of particulate debris and soluble substances, which differs qualitatively and quantitatively between native right coronary arteries (RCAs) and saphenous vein grafts on right coronary arteries (SVG-RCAs). We have now quantified the release of microparticles (MPs) during stent implantation into stable atherosclerotic lesions and compared the release between RCAs and SVG-RCAs.

METHODS: In symptomatic, male patients with stable angina and a stenosis in their RCA or SVG-RCA, respectively (n = 14/14), plaque volume and composition were analyzed using intravascular ultrasound before stent implantation. Coronary aspirate was retrieved during stent implantation with a distal occlusion/aspiration device and divided into particulate debris and plasma. Particulate debris was weighed. Platelet-derived MPs (PMPs) were distinguished by flow cytometry as CD41+, endothelium-derived MPs (EMPs) as CD144+, CD62E+ and CD31+/CD41-, leukocyte-derived MPs as CD45+, and erythrocyte-derived MPs as CD235+.

RESULTS: In patients with comparable plaque volume and composition in RCAs and SVG-RCAs, intracoronary PMPs and EMPs were increased after stent implantation into their RCAs and SVG-RCAs (CD41+: 2729.6 ± 645.6 vs. 4208.7 ± 679.4 and 2355.9 ± 503.9 vs. 3285.8 ± 733.2 nr/µL; CD144+: 451.5 ± 87.9 vs. 861.7 ± 147.0 and 444.6 ± 74.8 vs. 726.5 ± 136.4 nr/µL; CD62E+: 1404.1 ± 247.7 vs. 1844.3 ± 378.6 and 1084.6 ± 211.0 vs. 1783.8 ± 384.3 nr/µL, P < 0.05), but not different between RCAs and SVG-RCAs.

CONCLUSION: Stenting in stable atherosclerotic lesions is associated with a substantial release not only of PMPs, but also of EMPs in RCAs and SVG-RCAs. Their release does not differ between RCAs and SVG-RCAs.

TRIAL REGISTRATION: ClinicalTrials.gov NCT01430884.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты