DOI 10.1161/circheartfailure.119.006635

Медицинская библиотека · Circulation. Heart failure · 2019

Clinical Practice Patterns in Temporary Mechanical Circulatory Support for Shock in the Critical Care Cardiology Trials Network (CCCTN) Registry.

Berg David D, Barnett Christopher F, Kenigsberg Benjamin B, Papolos Alexander, Alviar Carlos L, Baird-Zars Vivian M, Barsness Gregory W, Bohula Erin A, Brennan Joseph, Burke James A, Carnicelli Anthony P, Chaudhry Sunit-Preet, Cremer Paul C, Daniels Lori B, DeFilippis Andrew P, Gerber Daniel A, Granger Christopher B, Hollenberg Steven, Horowitz James M, Gladden James D, Katz Jason N, Keeley Ellen C, Keller Norma, Kontos Michael C, Lawler Patrick R, Menon Venu, Metkus Thomas S, Miller P Elliott, Nativi-Nicolau Jose, Newby L Kristin, Park Jeong-Gun, Phreaner Nicholas, Roswell Robert O, Schulman Steven P, Sinha Shashank S, Snell R Jeffrey, Solomon Michael A, Teuteberg Jeffrey J, Tymchak Wayne, van Diepen Sean, Morrow David A

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Temporary mechanical circulatory support (MCS) devices provide hemodynamic assistance for shock refractory to pharmacological treatment. Most registries have focused on single devices or specific etiologies of shock, limiting data regarding overall practice patterns with temporary MCS in cardiac intensive care units.

METHODS

The CCCTN (Critical Care Cardiology Trials Network) is a multicenter network of tertiary CICUs in North America. Between September 2017 and September 2018, each center (n=16) contributed a 2-month snapshot of consecutive medical CICU admissions.

RESULTS

Of the 270 admissions using temporary MCS, 33% had acute myocardial infarction-related cardiogenic shock (CS), 31% had CS not related to acute myocardial infarction, 11% had mixed shock, and 22% had an indication other than shock. Among all 585 admissions with CS or mixed shock, 34% used temporary MCS during the CICU stay with substantial variation between centers (range: 17%-50%). The most common temporary MCS devices were intraaortic balloon pumps (72%), Impella (17%), and veno-arterial extracorporeal membrane oxygenation (11%), although intraaortic balloon pump use also varied between centers (range: 40%-100%). Patients managed with intraaortic balloon pump versus other forms of MCS (advanced MCS) had lower Sequential Organ Failure Assessment scores and less severe metabolic derangements. Illness severity was similar at high- versus low-MCS utilizing centers and at centers with more advanced MCS use.

CONCLUSIONS

There is wide variation in the use of temporary MCS among patients with shock in tertiary CICUs. While hospital-level variation in temporary MCS device selection is not explained by differences in illness severity, patient-level variation appears to be related, at least in part, to illness severity.

Для цитирования: Berg David D, Barnett Christopher F, Kenigsberg Benjamin B, Papolos Alexander, Alviar Carlos L, Baird-Zars Vivian M, Barsness Gregory W, Bohula Erin A, Brennan Joseph, Burke James A, Carnicelli Anthony P, Chaudhry Sunit-Preet, Cremer Paul C, Daniels Lori B, DeFilippis Andrew P, Gerber Daniel A, Granger Christopher B, Hollenberg Steven, Horowitz James M, Gladden James D, Katz Jason N, Keeley Ellen C, Keller Norma, Kontos Michael C, Lawler Patrick R, Menon Venu, Metkus Thomas S, Miller P Elliott, Nativi-Nicolau Jose, Newby L Kristin, Park Jeong-Gun, Phreaner Nicholas, Roswell Robert O, Schulman Steven P, Sinha Shashank S, Snell R Jeffrey, Solomon Michael A, Teuteberg Jeffrey J, Tymchak Wayne, van Diepen Sean, Morrow David A. Clinical Practice Patterns in Temporary Mechanical Circulatory Support for Shock in the Critical Care Cardiology Trials Network (CCCTN) Registry.. Circulation. Heart failure. 2019. DOI: 10.1161/circheartfailure.119.006635.