MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/19440049.2026.2633529

Медицинская библиотека · Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment · 2026

Development and validation of a multi-residue high-resolution mass spectrometry method for screening antimicrobial veterinary drug residues in eggs using LC-IMS-QTOF, with comparison to Q-orbitrap technology.

Guichard Pierre, Gaugain Murielle, Chailleux Annaëlle, Couëdor Pierrick, Hurtaud-Pessel Dominique, Verdon Eric

СтатьяВалидационное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

A qualitative high-resolution mass spectrometry (HRMS) screening method based on LC-IMS-QTOF was developed and validated for the simultaneous detection of 74 antimicrobial veterinary drug residues (VDRs) from 10 families in eggs. Detection was performed by electrospray ionisation in positive ion mode. The method was validated according to the Commission Implementing Regulation (EU) 2021/808, using maximum residue limits (MRLs) or minimum method performance requirements (MMPRs). Performance was assessed in triplicate across three acquisition modes: HDMSE (using ion mobility) and MSE (without ion mobility) on a Q-TOF system, and Full Scan-variable data-independent acquisition (FS-vDIA) on a Q-Orbitrap system. Both HRMS platforms proved suitable for regulatory monitoring of antimicrobial VDRs in eggs, with best performance achieved on the Q-TOF system without ion mobility or on the Q-Orbitrap system, enhancing sensitivity.

Для цитирования: Guichard Pierre, Gaugain Murielle, Chailleux Annaëlle, Couëdor Pierrick, Hurtaud-Pessel Dominique, Verdon Eric. Development and validation of a multi-residue high-resolution mass spectrometry method for screening antimicrobial veterinary drug residues in eggs using LC-IMS-QTOF, with comparison to Q-orbitrap technology.. Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment. 2026. DOI: 10.1080/19440049.2026.2633529.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.