DOI 10.1136/thoraxjnl-2015-207700

Медицинская библиотека · Thorax · 2016

Fixed-pressure CPAP versus auto-adjusting CPAP: comparison of efficacy on blood pressure in obstructive sleep apnoea, a randomised clinical trial.

Pépin J L, Tamisier R, Baguet J P, Lepaulle B, Arbib F, Arnol N, Timsit J F, Lévy P

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Millions of individuals with obstructive sleep apnoea (OSA) are treated by CPAP aimed at reducing blood pressure (BP) and thus cardiovascular risk. However, evidence is scarce concerning the impact of different CPAP modalities on BP evolution.

METHODS

This double-blind, randomised clinical trial of parallel groups of patients with OSA indicated for CPAP treatment compared the efficacy of fixed-pressure CPAP (FP-CPAP) with auto-adjusting CPAP (AutoCPAP) in reducing BP. The primary endpoint was the change in office systolic BP after 4 months. Secondary endpoints included 24 h BP measurements.

RESULTS

Patients (322) were randomised to FP-CPAP (n=161) or AutoCPAP (n=161). The mean apnoea+hypopnoea index (AHI) was 43/h (SD, 21); mean age was 57 (SD, 11), with 70% of males; mean body mass index was 31.3 kg/m(2) (SD, 6.6) and median device use was 5.1 h/night. In the intention-to-treat analysis, office systolic blood pressure decreased by 2.2 mm Hg (95% CI -5.8 to 1.4) and 0.4 mm Hg (-4.3 to 3.4) in the FP-CPAP and AutoCPAP group, respectively (group difference: -1.3 mm Hg (95% CI -4.1 to 1.5); p=0.37, adjusted for baseline BP values). 24 h diastolic BP (DBP) decreased by 1.7 mm Hg (95% CI -3.9 to 0.5) and 0.5 mm Hg (95% CI -2.3 to 1.3) in the FP-CPAP and AutoCPAP group, respectively (group difference: -1.4 mm Hg (95% CI -2.7 to -0.01); p=0.048, adjusted for baseline BP values).

CONCLUSIONS

The result was negative regarding the primary outcome of office BP, while FP-CPAP was more effective in reducing 24 h DBP (a secondary outcome).

TRIAL REGISTRATION NUMBER: NCT01090297.

Для цитирования: Pépin J L, Tamisier R, Baguet J P, Lepaulle B, Arbib F, Arnol N, Timsit J F, Lévy P. Fixed-pressure CPAP versus auto-adjusting CPAP: comparison of efficacy on blood pressure in obstructive sleep apnoea, a randomised clinical trial.. Thorax. 2016. DOI: 10.1136/thoraxjnl-2015-207700.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.