BACKGROUND

Cerebral computed tomography angiography (CTA) is widely used to assess neurovascular disorders, but venous contamination often obscures arteries. Optimizing bolus-tracking thresholds is crucial, yet patient factors influencing contrast dynamics and the value of radiation dose indices in head CTA remain unclear.

OBJECTIVES

To optimize bolus-tracking thresholds in cerebral CTA by examining patient-related influences on enhancement and radiation metrics.

METHODS

126 adults undergoing cerebral CTA were evaluated in this prospective study. Demographics, physiologic parameters, peak enhancement time (PET), peak enhancement attenuation (PEA), and dose indices (CTDIvol, SSDE) were recorded. Linear regression identified predictors of enhancement. Two blinded radiologists graded venous contamination. ROC analysis, including age subgroups, determined the optimal HU threshold.

RESULTS

Median age was 55.5 years; 70% were male. PET rose with age (+0.086 s/year, p < 0.001) and was shorter in females (-2.39 s, p = 0.003). PEA increased with threshold (+1.03 HU/unit, p < 0.001). Arterial enhancement was higher in females (+40.7 HU, p < 0.001) and patients ≥60 years (+70 HU, p < 0.001). Venous enhancement correlated with PET (p = 0.023) and systolic pressure (p = 0.002). ROC analysis showed an optimal threshold of 105 ± 5 HU (AUC = 0.634; sensitivity 88.4%, specificity 77.1%). CTDIvol, but not SSDE, correlated with weight (p = 0.015).

CONCLUSION

Intrinsic (age, gender) and extrinsic (threshold) factors shape CTA enhancement. A 105 ± 5 HU threshold reduces venous contamination, especially in younger patients. CTDIvol remains the preferred dose index. Findings support individualized, resource-efficient CTA protocols aligned with UN SDGs 3, 9, and 12.

Для цитирования: Prabhu Ashwin, Pradhan Abhimanyu, S Sharath, Kadavigere Rajagopal, Dkhar Winniecia, P S Priya, Sukumar Suresh, Reddy Pulagam Vamsidhar, Abraham Barnes Neil. Optimization of Bolus-Tracking Thresholds levels in Cerebral CT Angiography: Influence of Patient Characteristics on contrast enhancement dynamics and radiation dose metrics.. F1000Research. 2025. DOI: 10.12688/f1000research.171062.2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.