MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aor.14728

Медицинская библиотека · Artificial organs · 2024

Longitudinal cardiac dimensions in patients undergoing LVAD implantation.

Meissner Florian, Szvetics Sophie, Galbas Michelle Costa, Russe Maximilian, Schibilsky David, Kaier Klaus, Czerny Martin, Bothe Wolfgang

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In conventional left ventricular assist devices (LVAD), a separate outflow graft is sutured to the ascending aorta. Novel device designs may include a transventricular outflow cannula crossing the aortic valve (AV). While transversal ventricular dimensions are well investigated in patients with severe heart failure, little is known about the longitudinal dimensions. These dimensions are, however, particularly critical for the design and development of mechanical circulatory support (MCS) devices with transaortic outflow cannula.

METHODS

In an explorative retrospective cohort study at the University Medical Center Freiburg, Germany, the longitudinal cardiac dimensions of patients undergoing computed tomography angiography (CTA) before and, if available, after LVAD implantation were analyzed. Among others, the following dimensions were assessed: (a) apex to AV, (b) apex to mitral valve, (c) AV to sinotubular junction (STJ), (d) apex to STJ, (e) apex to brachiocephalic artery (BCA), and (f) AV to BCA.

RESULTS

In total, 44 LVAD patients (36 male, age 55.8 years, height 1.75 m) were included. The longitudinal cardiac dimensions were (a) 114.5 ± 12.1 mm, (b) 108.0 ± 12.4 mm, (c) 20.9 ± 2.9, (d) 135.4 ± 13.4 mm, (e) 206.0 ± 18.3, and (f) 91.5 ± 9.8 mm. Postoperatively, (a) and (b) decreased by 31.5% and 39.5%, respectively (N = 14).

CONCLUSIONS

Longitudinal cardiac dimensions may be reduced by up to 40% after LVAD implantation. A better knowledge of these dimensions and their postoperative alterations in LVAD patients may improve surgical planning and help to design MCS devices with transventricular outflow cannula.

Для цитирования: Meissner Florian, Szvetics Sophie, Galbas Michelle Costa, Russe Maximilian, Schibilsky David, Kaier Klaus, Czerny Martin, Bothe Wolfgang. Longitudinal cardiac dimensions in patients undergoing LVAD implantation.. Artificial organs. 2024. DOI: 10.1111/aor.14728.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.