Influence of repeated milling bur use on the marginal adaptation of monolithic zirconia crowns.

Akınal Mehmet Ali, Ergünbaş Bilge

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This in vitro investigation was designed to assess the vertical marginal discrepancies in monolithic zirconia crowns manufactured using CAD-CAM technology, specifically focusing on the effects of progressive deterioration associated with the cumulative use of tungsten carbide instruments.

MATERIALS AND

METHODS

Fifty-six monolithic zirconia crowns were manufactured utilizing a dry milling protocol. Milling was continued without bur replacement, and production proceeded with the same bur set even after the system issued a bur replacement warning after the 27th restoration. These restorations were then allocated into four distinct groups (n = 14 per group) based on the milling sequence. Marginal gap measurements were performed with a stereomicroscope, and measurements were obtained from the four surfaces of each crown. To evaluate statistical significance among the groups, a Welch analysis of variance (ANOVA) was conducted, followed by Games-Howell procedures for post hoc pairwise comparisons.

RESULTS

Significant variations in vertical marginal adaptation were detected among the tested cohorts (F = 68.5, P < .001). The mean ± SD (µm) values were as follows: G1 = 34.78 ± 5.89; G2 = 63.13 ± 14.53; G3 = 82.54 ± 17.61; and G4 = 99.69 ± 21.66. With the exception of Groups 3 and 4, which demonstrated statistically comparable outcomes (P = .126), all other pairwise comparisons yielded significant disparities. The marginal gap increased in parallel with the production sequence (r = 0.86, P < .001).

CONCLUSION

As the milling bur usage cycle increased, the marginal gap increased; however, the difference in marginal discrepancy between the later production groups (Group 3 and Group 4) was no longer statistically significant.

Для цитирования: Akınal Mehmet Ali, Ergünbaş Bilge. Influence of repeated milling bur use on the marginal adaptation of monolithic zirconia crowns.. The journal of advanced prosthodontics. 2026. DOI: 10.4047/jap.2026.18.4.337.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.