Аннотация

BACKGROUND

We evaluated the performance of conventional (C) single-photon emission computed tomography (SPECT) and cadmium-zinc-telluride (CZT)-SPECT in a large cohort of patients with suspected or known coronary artery disease (CAD) and compared the diagnostic accuracy of the two systems using machine learning (ML) algorithms.

METHODS AND

RESULTS

A total of 517 consecutive patients underwent stress myocardial perfusion imaging (MPI) by both C-SPECT and CZT-SPECT. In the overall population, an excellent correlation between stress MPI data and left ventricular (LV) functional parameters measured by C-SPECT and by CZT-SPECT was observed (all P < .001). ML analysis performed through the implementation of random forest (RF) and k-nearest neighbors (NN) algorithms proved that CZT-SPECT has greater accuracy than C-SPECT in detecting CAD. For both algorithms, the sensitivity of CZT-SPECT (96% for RF and 60% for k-NN) was greater than that of C-SPECT (88% for RF and 53% for k-NN).

CONCLUSIONS

MPI data and LV functional parameters obtained by CZT-SPECT are highly reproducible and provide good correlation with those obtained by C-SPECT. ML approach showed that the accuracy and sensitivity of CZT-SPECT is greater than C-SPECT in detecting CAD.

Для цитирования: Cantoni Valeria, Green Roberta, Ricciardi Carlo, Assante Roberta, Zampella Emilia, Nappi Carmela, Gaudieri Valeria, Mannarino Teresa, Genova Andrea, De Simini Giovanni, Giordano Alessia, D'Antonio Adriana, Acampa Wanda, Petretta Mario, Cuocolo Alberto. A machine learning-based approach to directly compare the diagnostic accuracy of myocardial perfusion imaging by conventional and cadmium-zinc telluride SPECT.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2020. DOI: 10.1007/s12350-020-02187-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.