[Evaluation of Drug Cost-Saving Effects of Drug Vial Optimization Using an Anticancer Drug Compounding Robot: A Single-center Study].

Sato Hikaru, Kato Ayami, Mino Yasuaki, Yagi Tatsuya, Aono Hironao, Uchida Chiaki, Kato Sayaka, Yamamoto Kazuki, Kawakami Junichi

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

This study aimed to evaluate the drug cost-saving effects of drug vial optimization (DVO) using an anticancer drug compounding robot in a single institution. Robotic preparations, drug costs, and wastage were evaluated from April to July 2022. Cost-saving simulations were conducted assuming same-day or 7-day DVO. From September to December 2022, DVO was performed for paclitaxel, carboplatin, and etoposide, and actual cost savings were evaluated. During the initial period, 2613 doses (42.0%) were prepared by the robot, with a wastage rate of 2.7%. The simulated cost savings were approximately ¥2.8 million (same-day) and ¥7.49 million (7-days). After the introduction of DVO, 291 vials were saved, equivalent to ¥790000. In conclusion, DVO using an anticancer drug compounding robot can reduce anticancer drug wastage and may contribute to drug cost savings in clinical practice.

Для цитирования: Sato Hikaru, Kato Ayami, Mino Yasuaki, Yagi Tatsuya, Aono Hironao, Uchida Chiaki, Kato Sayaka, Yamamoto Kazuki, Kawakami Junichi. [Evaluation of Drug Cost-Saving Effects of Drug Vial Optimization Using an Anticancer Drug Compounding Robot: A Single-center Study].. Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan. 2026. DOI: 10.1248/yakushi.26-00021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.