MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tnsre.2013.2239662

Медицинская библиотека · IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2013

Multi-pad electrode for effective grasping: design.

Popović-Maneski Lana, Kostić Milos, Bijelić Goran, Keller Thierry, Mitrović Sindi, Konstantinović Ljubica, Popović Dejan B

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

We designed a new surface multi-pad electrode for the electrical stimulation of the forearm that is effective in controlling functional grasp in hemiplegic patients. The electrode shape and size were designed on the basis of the surface stimulation map of the forearm, determined from measurements in seven hemiplegic patients who had limited or absent voluntary movements of the fingers, thumb and wrist. The stimulation map for each patient was assessed with a conventional set of single pad Pals Platinum electrodes. Since the sites for the stimulation varied greatly between patients, the end result was a rather large multi-pad electrode. Modulating multi-pad electrode size, shape, position and individual pad stimulation parameters allows us to accommodate the diversity of the neural tissues in patients that need to be activated for functional grasp. This also allows asynchronous activation of different portions of the muscle and dynamic adaptation of the stimulation sites to appropriate underlying tissues during functional use. The validity of the determined stimulation map was tested in the same group of hemiplegic patients. The selected set of active pads resulted in fully functional and reproducible palmar and lateral grasps similar to healthy-like grasps.

Для цитирования: Popović-Maneski Lana, Kostić Milos, Bijelić Goran, Keller Thierry, Mitrović Sindi, Konstantinović Ljubica, Popović Dejan B. Multi-pad electrode for effective grasping: design.. IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. 2013. DOI: 10.1109/tnsre.2013.2239662.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.