Comparison of SARS-CoV-2 Reverse Transcriptase Polymerase Chain Reaction and BinaxNOW Rapid Antigen Tests at a Community Site During an Omicron Surge : A Cross-Sectional Study.

Schrom John, Marquez Carina, Pilarowski Genay, Wang Chung-Yu, Mitchell Anthea, Puccinelli Robert, Black Doug, Rojas Susana, Ribeiro Salustiano, Tulier-Laiwa Valerie, Martinez Jacqueline, Payan Joselin, Rojas Susy, Jones Diane, Martinez Daniel, Nakamura Robert, Chamie Gabriel, Jain Vivek, Petersen Maya, DeRisi Joe, Havlir Diane

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

SARS-CoV-2 rapid antigen tests are an important public health tool.

OBJECTIVE

To evaluate field performance of the BinaxNOW rapid antigen test (Abbott) compared with reverse transcriptase polymerase chain reaction (RT-PCR) for detecting infection with the Omicron variant of SARS-CoV-2.

DESIGN

Cross-sectional surveillance study.

SETTING

Free, walk-up, outdoor, urban community testing and vaccine site led by Unidos en Salud, serving a predominantly Latinx community highly impacted by COVID-19.

PARTICIPANTS

Persons seeking COVID-19 testing in January 2022.

MEASUREMENTS: Simultaneous BinaxNOW and RT-PCR from nasal, cheek, and throat swabs, including cycle threshold (Ct) measures; a lower Ct value is a surrogate for higher amounts of virus.

RESULTS

Among 731 persons tested with nasal swabs, there were 296 (40.5%) positive results on RT-PCR; 98.9% were the Omicron variant. BinaxNOW detected 95.2% (95% CI, 91% to 98%) of persons who tested positive on RT-PCR with a Ct value below 30, 82.1% (CI, 77% to 87%) of those who tested positive on RT-PCR with a Ct value below 35, and 65.2% (CI, 60% to 71%) of all who were positive on RT-PCR. Among 75 persons with simultaneous nasal and cheek swabs, BinaxNOW using a cheek swab failed to detect 91% (20 of 22) of specimens that were positive on BinaxNOW with a nasal swab. Among persons with simultaneous nasal and throat swabs who were positive on RT-PCR with a Ct value below 30, 42 of 49 (85.7%) were detected by nasal BinaxNOW, 23 of 49 (46.9%) by throat BinaxNOW, and 44 of 49 (89.8%) by either.

LIMITATION: Participants were a cross-sectional sample from a community-based sentinel surveillance site, precluding study of viral or symptom dynamics.

CONCLUSION

BinaxNOW detected persons with high SARS-CoV-2 levels during the Omicron surge, enabling rapid responses to positive test results. Cheek or throat swabs should not replace nasal swabs. As currently recommended, high-risk persons with an initial negative BinaxNOW result should have repeated testing.

PRIMARY FUNDING SOURCE: University of California, San Francisco.

Для цитирования: Schrom John, Marquez Carina, Pilarowski Genay, Wang Chung-Yu, Mitchell Anthea, Puccinelli Robert, Black Doug, Rojas Susana, Ribeiro Salustiano, Tulier-Laiwa Valerie, Martinez Jacqueline, Payan Joselin, Rojas Susy, Jones Diane, Martinez Daniel, Nakamura Robert, Chamie Gabriel, Jain Vivek, Petersen Maya, DeRisi Joe, Havlir Diane. Comparison of SARS-CoV-2 Reverse Transcriptase Polymerase Chain Reaction and BinaxNOW Rapid Antigen Tests at a Community Site During an Omicron Surge : A Cross-Sectional Study.. Annals of internal medicine. 2022. DOI: 10.7326/m22-0202.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.