MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2015/930575

Медицинская библиотека · BioMed research international · 2015

Intraoperative scintigraphy using a large field-of-view portable gamma camera for primary hyperparathyroidism: initial experience.

Hall Nathan C, Plews Robert L, Agrawal Amit, Povoski Stephen P, Wright Chadwick L, Zhang Jun, Martin Edward W, Phay John

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We investigated a novel technique, intraoperative (99 m)Tc-Sestamibi (MIBI) imaging (neck and excised specimen (ES)), using a large field-of-view portable gamma camera (LFOVGC), for expediting confirmation of MIBI-avid parathyroid adenoma removal.

METHODS

Twenty patients with MIBI-avid parathyroid adenomas were preoperatively administered MIBI and intraoperatively imaged prior to incision (neck) and immediately following resection (neck and/or ES). Preoperative and intraoperative serum parathyroid hormone monitoring (IOPTH) and pathology (path) were also performed.

RESULTS

MIBI neck activity was absent and specimen activity was present in 13/20 with imaging after initial ES removal. In the remaining 7/20 cases, residual neck activity and/or absent ES activity prompted excision of additional tissue, ultimately leading to complete hyperfunctioning tissue excision. Postexcision LFOVGC ES imaging confirmed parathyroid adenoma resection 100% when postresection imaging qualitatively had activity (ES) and/or no activity (neck). The mean ± SEM time saving using intraoperative LFOVGC data to confirm resection versus first IOPTH or path result would have been 22.0 ± 2 minutes (specimen imaging) and 26.0 ± 3 minutes (neck imaging).

CONCLUSION

Utilization of a novel real-time intraoperative LFOVGC imaging approach can provide confirmation of MIBI-avid parathyroid adenoma removal appreciably faster than IOPTH and/or path and may provide a valuable adjunct to parathyroid surgery.

Для цитирования: Hall Nathan C, Plews Robert L, Agrawal Amit, Povoski Stephen P, Wright Chadwick L, Zhang Jun, Martin Edward W, Phay John. Intraoperative scintigraphy using a large field-of-view portable gamma camera for primary hyperparathyroidism: initial experience.. BioMed research international. 2015. DOI: 10.1155/2015/930575.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.