MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijsu.2015.01.005

Медицинская библиотека · International journal of surgery (London, England) · 2015

Two-phase (low-dose) computed tomography is as effective as 4D-CT for identifying enlarged parathyroid glands.

Campbell Michael J, Sicuro Paul, Alseidi Adnan, Blackmore C Craig, Ryan John A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Four-dimensional computed tomography (4D-CT) is often used for patients with primary hyperparathyroidism and non-definitive localization after Sestamibi scan (MIBI) and ultrasound (US), but may expose patients to unnecessary radiation, typically between 10 and 26 millisieverts (mSv). We hypothesize that a simpler two-phase CT protocol would have a similar sensitivity, specificity and accuracy to those published for 4D-CT, while exposing the patient to less radiation.

METHODS

We reviewed 54 patients with primary hyperparathyroidism and non-definitive localization studies who had a two-phase CT between 2009 and 2012 at our tertiary referral center.

RESULTS

The mean radiation dose of two-phase CT over the course of the study was 5.2 mSv (range 3.5 mSv-9.1 mSv). Two-phase CT had a 77% (CI = 65%-86%) sensitivity and an 87% (CI = 73%-95%) specificity to lateralize enlarged parathyroid glands to the correct side of the neck and a 58% (CI = 45%-68%) sensitivity and 91% (CI = 83%-94%) specificity to localize parathyroid tumors to the correct quadrant of the neck. The overall accuracy of two-phase CT to lateralize enlarged parathyroids was 81% (CI = 73%, 88%) and the accuracy to localize enlarged parathyroids was 79% (CI = 73%, 84%).

DISCUSSION: As a second line investigation two-phase CT has a similar sensitivity, specificity and accuracy to those published for 4D-CT in patients with non-localized, enlarged parathyroids with less radiation exposure. Two-phase CT can help localize enlarged parathyroid glands not definitively identified using MIBI and US.

CONCLUSION

Two-phase CT allows clinicians to accurately identify enlarged parathyroid glands while exposing the patient to less radiation than 4D-CT.

Для цитирования: Campbell Michael J, Sicuro Paul, Alseidi Adnan, Blackmore C Craig, Ryan John A. Two-phase (low-dose) computed tomography is as effective as 4D-CT for identifying enlarged parathyroid glands.. International journal of surgery (London, England). 2015. DOI: 10.1016/j.ijsu.2015.01.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.