DOI 10.1016/j.amjoto.2014.10.036
Radiographic evaluation of non-localizing parathyroid adenomas.
Аннотация
PURPOSE: Patients with primary hyperparathyroidism routinely undergo preoperative imaging to localize the abnormal gland to facilitate a guided parathyroidectomy. These techniques include neck ultrasound (US), dual phase planar technetium-99m ((99m)TC) sestamibi (MIBI) scans, single photon emission computed tomography (SPECT), combined SPECT/CT, and four dimensional CT scans (4D CT). Despite appropriate preoperative imaging, non-localization of abnormal glands does occur. This study aims to determine whether non-localization is the result of radiologic interpretive error or a representation of a subset of truly non-localizing parathyroid adenomas.
MATERIALS AND
METHODS
A retrospective study was performed; two senior radiologists reinterpreted the preoperative imaging (US and MIBI scans) of 30 patients with initially non-localizing studies. All patients underwent parathyroidectomy for primary hyperparathyroidism at a tertiary referral center. Both radiologists were blinded to the scores of his colleague. The results were compared for inter-reader reliability using Cohen's kappa test.
RESULTS
Twenty-nine of thirty nuclear studies were found to be negative on reinterpretation. The readers agreed in 86.67% of their observations, with a kappa (κ) value of 0.706 (SE=±0.131, 95% confidence interval for κ =0.449-0.962). One of eighteen ultrasounds had positive localizations on reexamination, however, the inter-observer agreement was only 55.6%, with a kappa value of 0.351 (SE=±0.139, and 95% confidence interval for κ =0.080-0.623). Overall, no statistically significant difference in preoperative and retrospective interpretation was found.
CONCLUSION
This study identifies a subset of parathyroid adenomas that do not localize on preoperative imaging despite sound radiographic evaluation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.