DOI 10.1016/j.jvir.2014.09.019

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2014

Adenoma localization for recurrent or persistent primary hyperparathyroidism using dynamic four-dimensional CT and venous sampling.

Ginsburg Michael, Christoforidis Gregory A, Zivin Sean P, Obara Piotr, Wroblewski Kristen, Angelos Peter, Grogan Raymon H, Kaplan Edwin L

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine if parathyroid venous sampling (PVS) combined with four-dimensional (4D) computed tomography (CT) improves sensitivity and accuracy of identification of parathyroid adenoma in patients with recurrent or persistent primary hyperparathyroidism (pHPT) and negative technetium-99m methoxyisobutyl isonitrile ((99m)Tc-MIBI) and ultrasound (US) scans.

MATERIALS AND

METHODS

Both PVS and 4D CT were performed in 28 patients with recurrent or persistent pHPT and negative (99m)Tc-MIBI and US examinations. Localization by 4D CT alone and in combination with PVS and lateralization by PVS alone were retrospectively assessed for correlation with surgical results. Suspected adenomas on 4D CT were said to correlate with PVS if venous drainage identified on CT corresponded to sites of elevated parathyroid hormone concentration on PVS. Lesions difficult to identify on 4D CT were lesions < 1 cm in longest dimension. Results of 4D CT were classified as positive, negative, or equivocal.

RESULTS

Surgery was performed in 22 of 28 patients. Surgery identified 23 parathyroid adenomas, 1 carcinoma, and 2 hyperplastic glands in 20 patients. 4D-CT alone localized 11 lesions in 10 patients. PVS helped localize 13 additional lesions in nine more patients and clarified two lesions that were equivocal on 4D CT. Comparing 4D CT alone with 4D CT plus PVS, the sensitivity increased from 50% to 95% (P = .004), and accuracy increased from 55% to 91% (P = .022). PVS lateralization had a sensitivity of 93.3%, positive predictive value of 66.7%, and accuracy of 63.6%.

CONCLUSIONS

PVS significantly improves 4D CT localization of parathyroid adenomas in patients undergoing repeat surgery for pHPT with negative (99m)Tc-MIBI and US.

Для цитирования: Ginsburg Michael, Christoforidis Gregory A, Zivin Sean P, Obara Piotr, Wroblewski Kristen, Angelos Peter, Grogan Raymon H, Kaplan Edwin L. Adenoma localization for recurrent or persistent primary hyperparathyroidism using dynamic four-dimensional CT and venous sampling.. Journal of vascular and interventional radiology : JVIR. 2014. DOI: 10.1016/j.jvir.2014.09.019.