Correlation of continuous glucose monitoring profiles with pregnancy outcomes in nondiabetic women.
Аннотация
OBJECTIVE
To determine whether hyperglycemic excursions detected by continuous glucose monitoring (CGM) correlate with birth weight percentile and other pregnancy outcomes, and whether CGM correlates better with these outcomes than a single glucose value from a 1-hour glucose challenge test (GCT).
STUDY
DESIGN
This was a prospective observational study of 55 pregnant patients without preexisting diabetes, who wore a CGM device for up to 7 days, between 24 and 28 weeks' gestation. The area under the curve (AUC) of hyperglycemic excursions above various thresholds (110, 120, 130, 140, and 180 mg/dL) was calculated. These AUC values, and results from a standard 50-g GCT, were correlated with our primary outcome of birth weight percentile, and secondary outcomes of unplanned operative delivery, pregnancy complications, delivery complications, fetal complications, and neonatal complications.
RESULTS
A consistent correlation was seen between all AUC thresholds and birth weight percentile (r = 0.29, p < 0.05 for AUC-110, -120, -130, and -140; r = 0.25, p = 0.07 for AUC-180). This correlation was stronger than that of 1-hour oral GCT (r = -0.02, p = 0.88). There was no association between AUC values and other outcomes.
CONCLUSIONS
Among nondiabetic pregnant patients, hyperglycemic excursions detected by CGM show a stronger correlation to birth weight percentile than blood glucose values obtained 1-hour after a 50-g oral GCT.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.