MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejcts/ezab111

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2021

Long-term results of tricuspid annuloplasty with 3-dimensional-shaped rings: effective and durable!

Carino Davide, Zancanaro Edoardo, Lapenna Elisabetta, Ruggeri Stefania, Denti Paolo, Iaci Giuseppe, Buzzatti Nicola, Calabrese Maria Chiara, Nascimbene Simona, Sala Alessandra, Castiglioni Alessandro, Alfieri Ottavio, De Bonis Michele

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

3-Dimensional (3D)-shaped rings are largely adopted for tricuspid annuloplasty, but evidence about their long-term results is scanty. The goal of this study was to analyse the long-term results of tricuspid annuloplasty with 3D-shaped rings.

MATERIALS AND

METHODS

A retrospective review of our prospectively maintained database was carried out to identify all patients who underwent tricuspid valve repair with 3D-shaped rings between January 2011 and December 2014. Kaplan-Meier methods were used to analyse long-term survival. Cumulative incidence function using death as the competitive outcome was used to estimate cardiac death.

RESULTS

A total of 168 patients were identified. The median age was 66 years. Eighty-two patients (49%) were in advanced New York Heart Association functional class III-IV. Atrial fibrillation (AF) was present in 101 (60%); the median ejection fraction was 60%. In 82 (49%) patients, a Medtronic 3D Contour annuloplasty ring was employed; in the remaining 86 (51%) patients, an Edwards MC3 ring was used. Cumulative incidence function of cardiac death, with non-cardiac death as a competing risk, was 1.9 ± 1.1%, 95% confidence interval (CI) (0.51-4.95) at 7 years. The cumulative incidence function of recurrence of tricuspid regurgitation (TR) ≥2+ at 7 years was 14 ± 3.17%, 95% CI (8.49-20.82). Recurrence of TR ≥2+ at 7 years was not significantly different between the Medtronic 3D Contour and the Edwards MC3 rings (P = 0.3). AF was identified as the only independent predictor of recurrence of TR ≥2+.

CONCLUSIONS

3D-shaped rings are effective and durable. TR recurrence was relatively low at 7 years and usually moderate (2+/4+) without a significant difference between the 2 types of rings. The role of AF as a predictor of TR recurrence was confirmed.

Для цитирования: Carino Davide, Zancanaro Edoardo, Lapenna Elisabetta, Ruggeri Stefania, Denti Paolo, Iaci Giuseppe, Buzzatti Nicola, Calabrese Maria Chiara, Nascimbene Simona, Sala Alessandra, Castiglioni Alessandro, Alfieri Ottavio, De Bonis Michele. Long-term results of tricuspid annuloplasty with 3-dimensional-shaped rings: effective and durable!. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2021. DOI: 10.1093/ejcts/ezab111.